P6010: Difference between revisions

From TekWiki
Jump to navigation Jump to search
(Created page with "The Tektronix P6010 is a probe designed primarily for use with the S-5 sampling head. <gallery> File:Tek p6010 1.JPG File:Tek p6010 2.JPG File:Tek p6010 3.JPG File:Tek p6...")
 
m (No mention of use for sampling inputs in the P6010 manual.)
 
(11 intermediate revisions by 4 users not shown)
Line 1: Line 1:
The Tektronix P6010 is a probe designed primarily for use with the [[S-5]] sampling head.
{{Probe Sidebar
|manufacturer=Tektronix
|model=P6010
|summary=~150 MHz, ×10, Passive Probe
|image=Tek p6010 1.JPG
|caption=P6010
|for=1 MΩ scope inputs
|introduced=(?)
|discontinued=(?)
|designers=
|manuals=
* [[Media:070-0495-01.pdf|Tektronix P6010 Manual]] (OCR)
}}


The ''' Tektronix P6010''' is a x10 miniature passive probe designed for use with Tektronix wide-band oscilloscopes.
{{BeginSpecs}}
{{Spec | Attenuation        | ×10 }}
{{Spec | Rise time          | ≤2 ns (probe), 7 ns with [[453]] scope }}
{{Spec | Bandwidth          | 150 MHz }}
{{Spec | Input impedance    | 10 MΩ // <10–14.5 pF, depending on cable length }}
{{Spec | Compensation range | 14-21 pF, factory compensated to 20 pF }}
{{Spec | Maximum voltage    | 500 V DC + peak AC, derate above 12 MHz }}
{{Spec | Cable length      | 3.5, 6, or 9 feet long, terminated in a [[BNC]] connector }}
{{EndSpecs}}
==Pictures==
<gallery>
<gallery>
File:Tek p6010 1.JPG
Tek p6010 1.JPG
File:Tek p6010 2.JPG
Tek p6010 2.JPG
File:Tek p6010 3.JPG
Tek p6010 3.JPG
File:Tek p6010 4.JPG
Tek p6010 4.JPG
File:Tek p6010 5.JPG
Tek p6010 5.JPG
File:Tek p6010 6.JPG
Tek p6010 6.JPG
P6010.jpg
</gallery>
</gallery>
[[Category:1 MΩ Oscilloscope probes]]

Latest revision as of 06:32, 14 February 2023

Tektronix P6010
~150 MHz, ×10, Passive Probe
P6010

Compatible with 1 MΩ scope inputs

Produced from (?) to (?)

Manuals


Manuals – Specifications – Links – Pictures

The Tektronix P6010 is a x10 miniature passive probe designed for use with Tektronix wide-band oscilloscopes.

Key Specifications

Attenuation  ×10
Rise time ≤2 ns (probe), 7 ns with 453 scope
Bandwidth 150 MHz
Input impedance 10 MΩ // <10–14.5 pF, depending on cable length
Compensation range 14-21 pF, factory compensated to 20 pF
Maximum voltage 500 V DC + peak AC, derate above 12 MHz
Cable length 3.5, 6, or 9 feet long, terminated in a BNC connector

Pictures