Engine Analyzer System: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
No edit summary
 
(20 intermediate revisions by 3 users not shown)
Line 1: Line 1:
[[File:Engine Analyzer 1.jpg | thumb | 350px | right]]
{{Instrument Sidebar
The '''Tektronix Engine Analyzer''' consists of a [[561A]] oscilloscope or a [[564]] storage scope,
|manufacturer=Tektronix
a specially designed Engine Analyzer Timebase (a modified [[2B67]]) with a rotational function
|model=Engine Analyzer System
generator input, and a modifIed [[3A74]] 4-channel amplifier providing separate inputs for
|class=Application-specific instrument
pressure (with a charge preamplifier), ignition, vibration, and crank-shaft rotation marker.
|series=560-series scopes
|summary=Scope/Sensor Bundle for ICE Analysis
|image=Engine Analyzer 1.jpg
|caption=Engine Analyzer System (catalog image)
|introduced=1967
|discontinued=1975
|designers=
|manuals=
* [[Media:070-0890-00.pdf|070-0890-00 Engine Analyzer Manual]]
}}
In the late 1950s, Tektronix began developing '''solutions for analysis of rotational machinery''', especially internal combustion engines.


The instrument package includes a rotational function generator (015-0108-0x),
==Chronology==
pressure (015-0117-00) and vibration (015-0116-00) transducers,
===1958-1961: ROTAN===
ignition pickoff (012-0139-00), magnetic pickup (015-0119-00), cables and carrying case.
The earliest implementation was the [[ROTAN]] system from 1958 that used a magnetic drum rotational encoder coupled to the engine. It was limited to 10,000 rpm. ''What was the commercial status of the 1958 ROTAN until 1961?''


The rotational function generator consists of a rotating film disk that is mechanically linked to the engine. 
===1961-1967: 183/182===
Through three printed, optically sensed patterns, it provides three selectable signals – a sawtooth
In the early 1960s, still under the ROTAN label, the [[183|183 Rotational Analyzer]] with its [[182|182 optoelectronic encoder]] allowed up to 20,000 rpm.
pattern linked to the crank angle, a  pulse pattern marking crank angle in 10°, 60° and 360°
increments, and a modified sine (6% second harmonic) representing piston volume as a function of crankshaft
angle.


Possible displays include
===1967-1975: 560-series Engine Analyzer package===
In 1967, Tek commercialized a package of instruments as the '''Tektronix Engine Analyzer'''.
 
It consists of a [[561A]] oscilloscope or a [[564]] storage scope, an optoelectronic rotational function generator, a specially designed Engine Analyzer Timebase (a modified [[2B67]]) with a rotational function
generator input), and a modified [[3A74]] 4-channel amplifier providing separate inputs for pressure (with a charge preamplifier), ignition, vibration, and crank-shaft rotation marker. 
 
The Engine Analyzer was applied to measurements on [[wikipedia:Internal combustion engine|Internal combustion engines]], and facilitated displays like
{{2ColBegin}}
* Pressure vs. time
* Pressure vs. time
* Pressure vs. volume
* Pressure vs. volume
Line 21: Line 35:
* Vibration analysis
* Vibration analysis
* Ignition analysis (timing, point arcing, spark plug condition etc.)
* Ignition analysis (timing, point arcing, spark plug condition etc.)
{{2ColEnd}}
The '''015-0126-00 Engine Analyzer Accessory Package''' included a [[015-0108-00]] rotational function generator, a [[015-0117-00]] pressure transducer, a [[015-0116-00]] vibration transducer, a [[015-0119-00]] magnetic pickup, a [[012-0139-00]] ignition pickoff, interconnecting cables, mounting material and shaft coupler, a [[011-0095-00]] charge amplifier calibrator, a carrying case, and the [[Media:070-0890-00.pdf|070-0890-00 manual]].
For a full system, a [[561A]] or [[564]] oscilloscope, a [[3A74|3A74 Mod. 730A]] four-channel vertical amplifier, and a [[2B67|2B67 Mod. 730A]] timebase were required.


The Engine Analyzer System was available from 1967 until 1975, when production of the 560 oscilloscope
The 015-0108-00 rotational function generator consists of a rotating film disk that is mechanically linked to the engine.
series was terminated. To allow the rotational function generator to be used with [[7000-series scopes]],
Through three printed, optically sensed patterns, it provides three selectable signals – a sawtooth pattern linked to the crank angle,  
Tek offered a combination of a modified timebase ([[7B53A]] MOD FB) and a [[TM500]] based power supply
a pulse pattern marking crank angle in 10°, 60° and 360° increments, and a modified sine (6% second harmonic) representing piston volume as a function of crankshaft angle.
([[PS501]]-1 MOD 730E) that were produced until 1985.


==Manuals==
===1975-1985: 7000-series and TM500===
* [http://w140.com/tek_engine_analyzer.pdf Engine Analyzer Manual (PDF)]
The Engine Analyzer System was available from 1967 until 1975, when production of the 560 oscilloscope series was terminated.
To allow the rotational function generator to be used with [[7000-series scopes]], Tek offered a combination of a modified
timebase ([[7B53A]] MOD FB) and a [[TM500]] based power supply ([[PS501]]-1 MOD 730E) that were produced until 1985.


==Links==
==Links==
* [[Media:Tekscope 1969 V1 N2 Apr 1969.pdf     | A New Insight Into Reciprocating Machinery.  Tekscope Vol. 1 No. 2, Apr 1969]]
* [[Media:Tek engine analyzer in catalog.pdf|Engine Analyzer Description in 1968 Catalog]]
* [[Media:062-1074-00.pdf | Engine Analysis Concepts. Jim Thurman, 1970]]
{{Documents|Link=Engine Analyzer System}}
* [http://w140.com/tek_engine_analyzer_in_catalog.pdf Engine Analyzer Description in 1968 Catalog (PDF)]
 
==Prices==
===560-series Engine Analyzer===
{| class="wikitable"
! Part
! 1969 price
! In 2023 Dollars
|-
| [[561B]] P7 oscilloscope || $560 || $4,700
|-
| Alternative: [[564B]] storage oscilloscope  || $995 || $8,300
|-
| [[2B67]] Mod. 730A Engine Analyzer amplifier || $375  || $3,100
|-
| [[3A74]] Mod. 730A Engine Analyzer timebase || $775  || $6,500
|-
| 015-0126-00 Engine Analyzer Accessory Package || $820 || $6,900
|}


==Pictures==
==Pictures==
Line 40: Line 77:
Engine Analyzer 2.jpg
Engine Analyzer 2.jpg
Engine Analyzer 3.jpg
Engine Analyzer 3.jpg
Tek 3a74 engine analyzer amplifier.jpg
</gallery>
</gallery>


[[Category:Introduced in 1968]]
 
[[Category:Special-purpose oscilloscopes]]
[[Category:Special-purpose oscilloscopes]]

Latest revision as of 02:06, 2 April 2024

Tektronix Engine Analyzer System
Scope/Sensor Bundle for ICE Analysis
Engine Analyzer System (catalog image)

Produced from 1967 to 1975

Manuals
(All manuals in PDF format unless noted otherwise)
Manuals – Specifications – Links – Pictures

In the late 1950s, Tektronix began developing solutions for analysis of rotational machinery, especially internal combustion engines.

Chronology

1958-1961: ROTAN

The earliest implementation was the ROTAN system from 1958 that used a magnetic drum rotational encoder coupled to the engine. It was limited to 10,000 rpm. What was the commercial status of the 1958 ROTAN until 1961?

1961-1967: 183/182

In the early 1960s, still under the ROTAN label, the 183 Rotational Analyzer with its 182 optoelectronic encoder allowed up to 20,000 rpm.

1967-1975: 560-series Engine Analyzer package

In 1967, Tek commercialized a package of instruments as the Tektronix Engine Analyzer.

It consists of a 561A oscilloscope or a 564 storage scope, an optoelectronic rotational function generator, a specially designed Engine Analyzer Timebase (a modified 2B67) with a rotational function generator input), and a modified 3A74 4-channel amplifier providing separate inputs for pressure (with a charge preamplifier), ignition, vibration, and crank-shaft rotation marker.

The Engine Analyzer was applied to measurements on Internal combustion engines, and facilitated displays like

  • Pressure vs. time
  • Pressure vs. volume
  • Pressure vs. crank angle
  • Vibration analysis
  • Ignition analysis (timing, point arcing, spark plug condition etc.)

The 015-0126-00 Engine Analyzer Accessory Package included a 015-0108-00 rotational function generator, a 015-0117-00 pressure transducer, a 015-0116-00 vibration transducer, a 015-0119-00 magnetic pickup, a 012-0139-00 ignition pickoff, interconnecting cables, mounting material and shaft coupler, a 011-0095-00 charge amplifier calibrator, a carrying case, and the 070-0890-00 manual.

For a full system, a 561A or 564 oscilloscope, a 3A74 Mod. 730A four-channel vertical amplifier, and a 2B67 Mod. 730A timebase were required.

The 015-0108-00 rotational function generator consists of a rotating film disk that is mechanically linked to the engine. Through three printed, optically sensed patterns, it provides three selectable signals – a sawtooth pattern linked to the crank angle, a pulse pattern marking crank angle in 10°, 60° and 360° increments, and a modified sine (6% second harmonic) representing piston volume as a function of crankshaft angle.

1975-1985: 7000-series and TM500

The Engine Analyzer System was available from 1967 until 1975, when production of the 560 oscilloscope series was terminated. To allow the rotational function generator to be used with 7000-series scopes, Tek offered a combination of a modified timebase (7B53A MOD FB) and a TM500 based power supply (PS501-1 MOD 730E) that were produced until 1985.

Links

Documents Referencing Engine Analyzer System

Document Class Title Authors Year Links
070-0890-00.pdf Manual Engine Analyzer System 1968
Tekscope 1969 V1 N2 Apr 1969.pdf Article A New Insight Into Reciprocating Machinery Bill Verhoef 1969
062-1074-00.pdf Book Measurement Concepts: Engine Analysis Jim Thurman 1970

Prices

560-series Engine Analyzer

Part 1969 price In 2023 Dollars
561B P7 oscilloscope $560 $4,700
Alternative: 564B storage oscilloscope $995 $8,300
2B67 Mod. 730A Engine Analyzer amplifier $375 $3,100
3A74 Mod. 730A Engine Analyzer timebase $775 $6,500
015-0126-00 Engine Analyzer Accessory Package $820 $6,900

Pictures