TDS510A: Difference between revisions

From TekWiki
Jump to navigation Jump to search
(Moved TDS510 to TDS510A as this is the only variant in the TDS510 line.)
Tag: Removed redirect
(Added manuals)
 
(6 intermediate revisions by 2 users not shown)
Line 1: Line 1:
{{Oscilloscope Sidebar |manufacturer=Tektronix |series=TDS series scopes|designers=|
{{Oscilloscope Sidebar  
model= TDS510|
|manufacturer=Tektronix  
image=TDS510A.jpg|
|series=TDS series scopes
caption=Tektronix TDS510A |
|model=TDS510
introduced=(?) |
|image=TDS510A.jpg
discontinued=(?) |
|caption=Tektronix TDS510A
summary=500 MHz / 500 MS/s digital scope |
|introduced=(?)
manuals=
|discontinued=(?)
* [[Media:070-9701-03.pdf|TDS510A User Manual 070-9701-03]]
|summary=500 MHz / 500 MS/s digital scope
* [[Media:070-9704-02.pdf|TDS510A Service Manual 070-9704-02]]
|manuals=
* [[Media:070-8567-01.pdf|Option 13 RS-232/Centronics Hardcopy Interface Instruction Manual 070-8567-01]]
* [[Media:070-8582-01.pdf|Option 2F Advanced DSP Math Instruction Manual 070-8582-01]]
* [[Media:070-9701-02.pdf|TDS420A/430A/460A/510A User Manual 070-9701-02]]
* [[Media:070-9701-03.pdf|TDS420A/430A/460A/510A User Manual 070-9701-03]]
* [[Media:070-9704-02.pdf|TDS510A Service 070-9704-02]]
* [[Media:070-9706-00.pdf|TDS510A Performance Verification and Specifications 070-9706-00]]
* [[Media:070-9706-00.pdf|TDS510A Performance Verification and Specifications 070-9706-00]]
* [[Media:070-9758-00.pdf|TDS510A Reference 070-9758-00]]
* [[Media:070-9758-00.pdf|TDS510A Reference 070-9758-00]]
* [[Media:070-9876-00.pdf|TDS400A/500/600B/700C Programmers Manual 070-9876-00]]
* [[Media:TDS510A_Datasheet.pdf|Sales Brochure]]
* [[Media:TDS510A_Datasheet.pdf|Sales Brochure]]
}}
}}
The '''Tektronix TDS510''' is a 500 MS/s, 500 MHz four-channel digital scope.
The '''Tektronix TDS510''' is a 500 MS/s, 500 MHz four-channel digital scope.


{{MissingSpecs}}
{{BeginSpecs}}
{{Spec | Bandwidth        | 500 MHz  }}
{{Spec | Rise time        | 500 ps  }}
{{Spec | Sample rate      | 500 MS/s (1 or 2 channels used) / 250 MS/s (3 or 4 channels used)  }}
{{Spec | Time base        | 500 ps/Div to 10 s/Div    }}
{{Spec | Deflection      | 1 mV/Div to 10 V/Div    }}
{{Spec | Resolution      | 8 bits    }}
{{Spec | Record length    | 500 to 15 k points    }}
{{Spec | Input impedance  | 1 MΩ / 50 Ω                    }}
{{Spec | Interface        | [[GPIB]] standard            }}
{{Spec | Options 13 |
* [[Centronics interface]]
* [[RS-232 interface]]
}}
{{EndSpecs}}
 
==Software==
* [[Media:063-1134-00 V1.2.zip|TDS Family Programming Examples Software 063-1134-00 V1.2]] (zip)
* [[Media:066-0002-00.zip|Waveform Converter For Oscilloscopes 066-0002-00]] (ZIP)
* [[Media:066-0087-00.zip|AWE Drivers For Tektronix Oscilloscopes 066-0087-00]] (ZIP)
* [[Media:066-0104-00.zip|File Transfer Utility From TDS Scope To PC 066-0104-00]] (ZIP)
* [[Media:Ttip.zip|Telecom Test and I-Pattern Software TTiP 066-0119-00]] (ZIP)
* [[Media:066-0125-00.zip|Enhanced Printing Utility for TDS Family 066-0125-00]] (ZIP)
* [[Media:Tdsrteup_(TDS_runtime_Environment_TDSRTE1).zip|TDS runtime Environment TDSRTE1 066-0127-00]] (ZIP)
* [[Media:066-0176-00.zip|WFM to ASCII Waveform Converter - UNIX Version For Sun Spark Stations 066-0176-00]] (ZIP)
* [[Media:066-0177-00.zip|Hardcopy from TDS to PC Using HPIP 82335B Interface Card 066-0177-00]] (ZIP)
* [[Media:066-0178-00.zip|Example Program To Get Crossing Levels 066-0178-00]] (ZIP)
* [[Media:066-0179-00.zip|TDS ISF File To CSV File Conversion Utility 066-0179-00]] (ZIP)
* [[Media:066-0183-00.zip|TDS Sandisk Hard Disk Patch Utility 066-0183-00]] (ZIP)
* [[Media:066-0188-00.zip|Transfer 2 Byte Data From TDS Oscilloscopes QuickBasic 066-0188-00]] (ZIP)
* [[Media:066-0194-00.zip|TDS Waveform Logging Sample Program 066-0194-00]] (ZIP)
* [[Media:066-0196-00.zip|Load TDS Floppy MathCAD Files Into MathCAD 066-0196-00]] (ZIP)
* [[Media:066-0197-00.zip|Transfer TDS Hardcopy Screens To PC Via GPIB 066-0197-00]] (ZIP)
* [[Media:066-0198-00.zip|Transfer Setups Between TDS Oscilloscopes 066-0198-00]] (ZIP)
* [[Media:066-0200-00.zip|VB Program To Capture TDS Extended Waveforms 066-0200-00]] (ZIP)
* [[Media:066-0489-00.zip|TDS Series WFM File Formatter 066-0489-00]] (ZIP)
* [[Media:066-0201-00.zip|Telecommunications Option for TDS Oscilloscopes 066-0201-00]] (ZIP)
* [[Media:Wavestar_2012.05.09.11.07.29_16456_EN.zip|Tektronix Wavestar V3.0 2012.05.09.11.07.29 16456 EN]] (ZIP, 102MB) ''Product Key: WSTRO618650124''


==Links==
==Options==
*05 - Video Trigger
*13 - RS-232/Centronics hardcopy interface
*1K - [[K420]] Oscilloscope Cart without power strip
*1R - Rackmount
*2F - Advanced DSP Math
*95 - Test Data Report


{{MissingPics}}
{{MissingPics}}

Latest revision as of 22:09, 1 March 2023

Manuals – Specifications – Links – Pictures

The Tektronix TDS510 is a 500 MS/s, 500 MHz four-channel digital scope.

Key Specifications

Bandwidth 500 MHz
Rise time 500 ps
Sample rate 500 MS/s (1 or 2 channels used) / 250 MS/s (3 or 4 channels used)
Time base 500 ps/Div to 10 s/Div
Deflection 1 mV/Div to 10 V/Div
Resolution 8 bits
Record length 500 to 15 k points
Input impedance 1 MΩ / 50 Ω
Interface GPIB standard
Options 13

Software

Options

  • 05 - Video Trigger
  • 13 - RS-232/Centronics hardcopy interface
  • 1K - K420 Oscilloscope Cart without power strip
  • 1R - Rackmount
  • 2F - Advanced DSP Math
  • 95 - Test Data Report