1481/Repairs: Difference between revisions

From TekWiki
Jump to navigation Jump to search
(Created page with "1481R Vertical Scan fault whereby v scan is crushed as position is moved up. Corrected by replacing Q1617 (used to hand 2N2891 to replace 151-044600) 1481C No video, just horizontal line Noted that many semiconductors on vid/vscan board are in sockets (presumably for easy selection on test). By wiggling these socketed components in their sockets, video was restored.")
 
No edit summary
Line 1: Line 1:
1481R
1481R -
Vertical Scan fault whereby v scan is crushed as position is moved up.  
Vertical Scan fault whereby v scan is crushed as position is moved up. Corrected by replacing Q1617 (used to hand 2N2891 to replace 151-044600).
Corrected by replacing Q1617 (used to hand 2N2891 to replace 151-044600)
1481C -
1481C
No video, just horizontal line
No video, just horizontal line
Noted that many semiconductors on vid/vscan board are in sockets (presumably for easy selection on test).
Noted that many semiconductors on vid/vscan board are in sockets (presumably for easy selection on test).
By wiggling these socketed components in their sockets, video was restored.
By wiggling these socketed components in their sockets, video was restored.

Revision as of 03:18, 9 February 2025

1481R - Vertical Scan fault whereby v scan is crushed as position is moved up. Corrected by replacing Q1617 (used to hand 2N2891 to replace 151-044600).

1481C - 

No video, just horizontal line Noted that many semiconductors on vid/vscan board are in sockets (presumably for easy selection on test). By wiggling these socketed components in their sockets, video was restored.