Line 2: | Line 2: | ||
Maximum voltage is 600 V peak-to-peak. | Maximum voltage is 600 V peak-to-peak. | ||
It connects to the scope with a [[UHF connector]]. | It connects to the scope with a [[UHF connector]]. | ||
It was made for slower Tek scopes, up to [[535|Type 535]]. The cable is standard 50 Ω coax, which rings above 10 MHz. | |||
This aberration is not visible on slower displays, but the 30 MHz [[545|Type 545]] necessitated a new probe, the [[P410|P400 Series]]. | |||
* [http://w140.com/tek_p510a.pdf Tektronix P510A Schematic and Description (PDF)] | * [http://w140.com/tek_p510a.pdf Tektronix P510A Schematic and Description (PDF)] | ||
[[Category:1 MOhm Oscilloscope Probes]] | [[Category:1 MOhm Oscilloscope Probes]] |
Revision as of 09:05, 4 August 2017
The Tektronix P510A is a 10x passive voltage probe. Maximum voltage is 600 V peak-to-peak. It connects to the scope with a UHF connector.
It was made for slower Tek scopes, up to Type 535. The cable is standard 50 Ω coax, which rings above 10 MHz. This aberration is not visible on slower displays, but the 30 MHz Type 545 necessitated a new probe, the P400 Series.