Revision as of 12:09, 6 June 2020
The Tektronix 3A5 is a 15 MHz "Automatic/Programmable Amplifier" plug-in for 560-series scopes. It can automatically seek and select a suitable deflection factor to display an unknown signal.
Range seeking is initiated through a switch on the unit, a button on the P6030 probe, or a signal through the PROGRAM connector (using a 263 programmer).
The 3B5 is a time base with similar features.
Key Specifications
Deflection | 1 mV/Div to 50 V/Div , 1−2−5 |
---|---|
Bandwidth | 15 MHz (50 V/Div to 10 mV/Div), 5 MHz (5 mV/Div to 1 mV/Div) |
Seeking circuit frequency range | 30 Hz to 20 MHz |
Input impedance | 1 MΩ // 24 pF |
Links
- Tektronix 3A5 and 3B5 Automatic Seeking Mode @ YouTube
- Automatic / Programmable Plug-ins @ vintagetek.org
- Tek 3A5 @ barrytech.com
Pictures
-
3A5 front
-
3A5 gray front
-
3A5 inside left
-
3A5 inside right
-
Manual mode block diagram