465: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
Line 15: Line 15:
* [[Media:070-1861-00_C.pdf|465 Service B250000+]] (Color OCR PDF, 58M)
* [[Media:070-1861-00_C.pdf|465 Service B250000+]] (Color OCR PDF, 58M)
* [[Media:070-2191-00.pdf|465 Option 5 Supplement]] (PDF)
* [[Media:070-2191-00.pdf|465 Option 5 Supplement]] (PDF)


====465B====
====465B====
Line 21: Line 22:
* [http://w140.com/465b_trig2.pdf Tektronix 465B Trigger Generator Schematic (PDF)]
* [http://w140.com/465b_trig2.pdf Tektronix 465B Trigger Generator Schematic (PDF)]
* [[Media:465b_schematic.pdf|Tektronix 465B Trigger Generator Schematic (PDF, OCR, bad-OCR)]]
* [[Media:465b_schematic.pdf|Tektronix 465B Trigger Generator Schematic (PDF, OCR, bad-OCR)]]
* [[Media:050-1558-00.pdf|Modification: U3165 Replacement]]


<small>
<small>

Revision as of 21:34, 18 June 2019

{{{manufacturer}}} 
Portable 100 MHz dual-trace scope
Tektronix 465 front

Produced from 1972 to 1983

Manuals

465


465B

Modifications

History

(All manuals in PDF format unless noted otherwise)
Manuals – Specifications – Links – Pictures


The Tektronix 465 is a portable 100 MHz dual-trace oscilloscope with dual time-bases. The 465 was very popular and Tek made them for quite a few years. It is all solid-state except for the CRT. It was introduced in November 1972.

There was no 465A but a 465B (int. 1980) with the same base specs but improved performance. The 475 is a 200 MHz sister model. See also 465M.

The optional DM44 multimeter attaches to the top of the instrument.

Bill Turner worked as a calibration technician for the 465 oscilloscope group.

Key Specifications

}
Bandwidth DC to 100 MHz on CH1 & CH2 for −15°C to +40°C and DC to 85 MHz from +40°C to +55°C
Rise time 3.5 ns for 0°C to +40°C and 4.2 ns from +40°C to +55°C
Input Impedance 1 MΩ ±2% // 20 pF
Maximum Input Voltage 500 V DC (250 VDC when DC coupled) + Peak AC or 500 Vp-p AC at < 1 kHz
Trigger Coupling Modes DC, AC, LF Reject, HF Reject
Channel Isolation 100:1 at 25 MHz
Z Axis Input 5 Vp-p signal causes noticeable modulation at normal intensity
Z Axis Frequency response DC to 50 MHz
Output Signals CH1 Vertical, A & B +Gate
Calibrator Output ~1 kHz, 300 mV, square wave
CRT Graticule Area 8 cm × 10 cm
CRT Phosphor P31
CRT Accelerating Potential 18.5 kV
Line Voltage 110/115/120/220/230/240 VAC ±10%, selected via primary voltage selector and regulating range selector assembly, 48 Hz to 440 Hz
Power Consumption 75 W @ 115 VAC / 60 Hz

Internals

The 465 uses tunnel diodes with Tek part number 152-0125-00, which are equivalent to TD3A, and 155-0032-00 chips (their -01 grade) as trigger amplifiers. The CRT is part number 154-0676-10.

Links

Pictures

465