543: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
No edit summary |
||
Line 2: | Line 2: | ||
[[letter-series and 1-series plug-ins]]. It is similar to a [[545]], but without the second, delayed timebase. | [[letter-series and 1-series plug-ins]]. It is similar to a [[545]], but without the second, delayed timebase. | ||
Instead, it has a range of horizontal magnifiers from X2 to X100. It has the same six-stage | Instead, it has a range of horizontal magnifiers from X2 to X100. It has the same six-stage | ||
balanced distributed | balanced [[distributed amplifier]] (twelve [[6DK6]] tubes) as the 545. | ||
While the 545 has two non-calibrated X-input sensitivities, the 543 has | While the 545 has two non-calibrated X-input sensitivities, the 543 has | ||
an X-input with three calibrated selectable deflection sensitivities: 0.1V/cm, 1V/cm, and | an X-input with three calibrated selectable deflection sensitivities: 0.1V/cm, 1V/cm, and |
Revision as of 20:32, 8 February 2012
The Tektronix Type 543 is an all-tube 30MHz scope introduced in 1958. It takes letter-series and 1-series plug-ins. It is similar to a 545, but without the second, delayed timebase. Instead, it has a range of horizontal magnifiers from X2 to X100. It has the same six-stage balanced distributed amplifier (twelve 6DK6 tubes) as the 545. While the 545 has two non-calibrated X-input sensitivities, the 543 has an X-input with three calibrated selectable deflection sensitivities: 0.1V/cm, 1V/cm, and 10V/cm.