Line 1: |
Line 1: |
| {{Oscilloscope Sidebar |
| |
| title=Tektronix RSA5103B |
| |
| summary=Spectrum Analyzer 1 Hz to 3 GHz | to 6.2 GHz (RSA5106) to 15 GHz (RSA5115) to 26.5 GHz (RSA5126)
| |
| image= RSA5103A.jpg |
| |
| caption=Tektronix RSA5103B |
| |
| introduced=(?) |
| |
| discontinued=(?) |
| |
| manuals=
| |
| Need Service and Programmers Manuals
| |
| * [[Media: 37W-26274-19_RSA5000-Series-Spectrum-Analyzers-Datasheet.pdf | 37W-26274-19 RSA5000 Series Spectrum Analyzers Datasheet (PDF, OCR)]]
| |
| * [[Media: 071-3224-11_RSA5100B-Real-Time-Spectrum-Analyzer-Quick-Start-User-Manual-EN.pdf | 071-3224-11 RSA5100B Real-Time Spectrum Analyzer Quick Start User Manual (PDF, OCR)]]
| |
| * [[Media: 071-3283-00_RSA5100B-Real-Time-Spectrum-Analyzers-Application-Examples-Reference-EN.pdf | 071-3283-00 RSA5100B Real Time Spectrum Analyzers Application Examples Reference (PDF, OCR)]]
| |
| }}
| |
|
| |
|
| The '''RSA5103B''' is a laboratory grade spectrum analyzer with a frequency range of 1 Hz to 3 GHz. (6.2 GHz (RSA5106), 15 GHz (RSA5115), 26.5 GHz (RSA5126)) It provides small signal duration for 100% probability of intercept of 0.434 µsec (Opt. 300) and high real-time spurious-free dynamic range of 80 dB over the entire acquisition bandwidth with HD options (Opts. B85HD, B125HD, and B16xHD). In additional it operates not only as a spectrum analyzer but also wideband vector signal analyzer, and unique trigger-capture-analyze capability.
| |
|
| |
| The RSA’s has a 10.4 inch color touch panel display, 1 GB memory for acquisition (upgradeble to 4 GB, Opt. 53), an optional 480 GB internal hard drive (Opt. WIN10RINT), as well as an optional 480 GB removable solid-state drive (Opt. WIN10REM) to save and load data and settings.
| |
|
| |
| Tektronix real-time analyzers have a frequency mask trigger which allows the user to set up a spectral mask to capture a signal when a spectral anomaly occurs. DPX technology allows the user to view an RF signal as a live display. One can view very short transient signals, multilevel signals, and time-varying events. The analyzer allows the user to view the captured signals in a variety of time-correlated displays. Multiple displays can show different views of the same data live or saved.
| |
|
| |
| This RSA allows the use of multiple displays for advanced functionality. Some of these display categories include: General Signal Viewing displays; Analog Modulation; General Purpose Digital Modulation displays (Opt. 21); RF Measurements displays (Opt. 11); OFDM Analysis (Opt. 22); Advanced Pulse Analysis (Opt. 20); Audio Analysis (Opt. 10); WLAN Analysis (Opts 23, 34, and 25); Bluetooth LE and Bluetooth Basis Rate RF (Opt. 27); APCO P25 Analysis (Opt. 26); LTE Downlink Analysis (Opt. 28); Signal Classification (Opt. 54); Return Loss (Opt. 60), and Noise Figure (Opt. 14).
| |
|
| |
| Offline analysis can be performed with either or both the [[SignalVu-PC]] and [[RSAVu]].
| |
|
| |
| Front panel inputs/outputs are: RF INPUT [[N connector]] (RSA5103 and RSA5106 N; RSA5115 and RSA5126 Planar Crown) (50Ω, +30 dBm w/pre-amp off, +20 dBm w/pre-amp on); Trig IN [[BNC connector]] (External trigger input; -2.5 V to +2.5 V range); Trig OUT [[BNC connector]] (Trigger output; 50Ω, high > 2.0 V, low < 0.4 V, 1 mA); and 2 X [[USB connector]]s (USB 2.0).
| |
|
| |
| Rear panel inputs/outputs: GPIB [[GPIB connector]] (IEEE 488.2); Analog Zero Span Out [[BNC connector]] (Opt. 66); Real Time I and Q out [[MDR connector]]s (Opt. 65); Noise Source Drive [[BNC connector]] (+28 V DC Out, 140 mA (nominal), turn ON time: 100 µs, turn OFF time: 500 µs); LINE OUT [[Phone connector]] (Headphone audio out); MIC [[Phone connector]] (Microphone in); NOT IN USE [[Phone Connector]] (Line In not supported); Trig 2 In [[BNC connector]] (External trigger TTL 7V Max); COM 2 [[DB9 connector]] (Male pins, serial port for connecting peripherals); VGA [[VGA Connector]] (External monitor, resolution not limited to VGA); Keyboard [[Mini DIN connector]] (PS2 Keyboard); 2 X USB 2.0 [[USB connector]]s (For mouse and other peripherals); LAN [[Ethernet]] connector (RJ45 10/100/1000 Base T network); REF OUT [[BNC connector]] (Reference frequency, 10 MHz, >0 dBm, 5V Max); REF IN [[BNC connector]] (Reference frequency, 10 MHz, -10 dBm to +5 dBm, 5V Max); and US Power Plug (115 V nominal) .
| |
|
| |
| {{BeginSpecs}}
| |
| {{Spec | Frequency Range | 1 Hz to 3 GHz }} (6.2 GHz (RSA5106), 15 GHz (RSA5115), 26.5 GHz (RSA5126))
| |
| {{Spec | Real-time acquisition BW | 25 MHz, 40 MHz, 85 MHz, 125 MHz, 165 MHz }}
| |
| {{Spec | RF Input impedance | 50 Ω }}
| |
| {{Spec | Maximum Safe RF Input Power | +30 dBm (RF Input, RF ATT≥10 dB, Pre-amp Off); +20 dBm (RF Input, RF ATT≥10 dB, Pre-amp On); +50 Watts peak (RF Input, RF ATT≥30 dB (<10 µs, 1% Duty Cycle repetitive Pulses)) }}
| |
| {{Spec | Input Attenuator Range | 0 dB to 55 dB (5 dB step) }}
| |
| {{Spec | Dynamic Range (Spurious Free) | >75 dBc (25/40 MHz); > 73 dBc (85/165 MHz); ≥ 80 dBc (Opts. B85HD, B125HD, and B16xHD) }}
| |
| {{Spec | Reference Level Range | -170 dBm to +50 dBm (0.1 dB step) (min ref. level -50 dBm at center frequency <80 MHz) }}
| |
| {{Spec | Resolution Bandwidth Range | 0.1 Hz to 5 MHz (10 MHz with Opt. B85, 20 MHz with Opt. B16x), 1, 2, 3, 5 sequence, Auto-coupled, or user selected (arbitrary) }}
| |
| {{Spec | Video Bandwidth Range | 1 Hz to 10 MHz plus wide open }}
| |
| {{Spec | Minimum Signal Duration for 100% POI | 2.7 µs at 165 MHz BW (0.434 µs, Opt. 300); 2.8 µs at 85 MHz BW (0.551 µs, Opt. 300); 3.0 µs at 40 MHz BW (0.79 µs, Opt. 300); 3.2 µs at 25 MHz BW (0.915 µs, Opt. 300) }}
| |
| {{Spec | Trigger Modes | Free run, Triggered, FastFrame }}
| |
| {{Spec | Trigger Types | Power, Frequency mask, Frequency edge, DPX density, Runt, Time qualified }}
| |
| {{Spec | Ext Trigger Threshold Levels | High +1.6 to +5 V, Low 0 to +0.5 V }}
| |
| {{Spec | High-speed Sweeps with high resolution and low noise | 1 GHz sweeps at 10 kHz RBW in <1 sec }}
| |
| {{Spec | Displayed Average Noise | −142 dBm/Hz at 26.5 GHz, -157 dBm/Hz at 2 GHz, -150 dBm/Hz at 10 kHz }}
| |
| {{Spec | Phase Noise | –113 dBc/Hz at 1 GHz and –134 dBc/Hz at 10 MHz carrier frequency, 10 kHz offset }}
| |
| {{Spec | Included Accessories | Quick-Start Manual (printed), Application Guide, Printable Online Help File, Programmer’s manual (on CD), power cord, BNC to N adapter (RSA5103 and RSA5106; RSA5115 includes Planar Crown RF Input Connector to Type N female; RSA5126 includes Planar Crown RF Input Connector to 3.5 mm Female), USB Keyboard, USB Mouse, and Front Cover }}
| |
| {{Spec | Weight (all options) | 29 kg (64.7 lbs) }}
| |
| {{Spec | Power & Dissipation (fully loaded) | 100 − 240 V<sub>RMS</sub>, 50 to 60 Hz, 115 V<sub>RMS</sub>, 400 Hz, 450 W max }}
| |
| {{Spec | Operating Atmospherics | Temperatures: +5 °C to +40 °C; Humidity: 95% at +40°C; Altitude: Up to 3000 m (9842 ft) }}
| |
| {{EndSpecs}}
| |
|
| |
| == Optional Accessories==
| |
| * RTPA2A: Real-Time Spectrum Analyzer Probe Adapter; Supports TekConnect probes P7225, P7240, P7260, P7313, P7313SMA, P7330, P7340A, P7350, P7350SMA, P7360A, P7380A, P7380SMA, P7500 Series.
| |
| * [[SignalVu-PC]]: Offline analysis software based on the RSA5000/6000 Series platform.
| |
| * [[RSAVu]]: Offline analysis software based on the RSA3000 platform for analysis supporting 3G wireless standards
| |
| * Planar Crown 3.5 mm female connector, Tektronix part number 131-9062-00.
| |
| * Planar Crown 3.5 mm male connector, Tektronix part number 131-8822-00.
| |
| * Planar Crown Type N female connector, Tektronix part number 131-4329-00.
| |
| * Planar Crown SMA female connector, Tektronix part number 131-8689-00.
| |
| * Transit Case – Tektronix part number 016-1963-00.
| |
| * Rackmount Retrofit - RSA56KR.
| |
|
| |
| ==Options==
| |
| * Opt. 09: Adds Enhanced Real Time.
| |
| * Opt. 10: Adds AM/FM/PM and Audio Analysis.
| |
| * Opt. 11: Adds Phase Noise and Jitter Measurement.
| |
| * Opt. 12: Adds Settling Time Measurement (Frequency and Phase).
| |
| * Opt. 14: Adds Noise Figure and Gain Measurement.
| |
| * Opt. 20: Adds advanced signal analysis (including pulse measurements).
| |
| * Opt. 21: Adds general-purpose digital modulation analysis.
| |
| * Opt. 22: Adds flexible OFDM analysis.
| |
| * Opt. 23: Adds WLAN 802.11a/b/g/j/p analysis.
| |
| * Opt. 24: Adds WLAN 802.11n analysis.
| |
| * Opt. 25: Adds WLAN 802.11ac analysis.
| |
| * Opt. 26: Adds APCO P25 measurement application.
| |
| * Opt. 27: Adds Bluetooth LE and Bluetooth Basic Rate RF transmitter measurements.
| |
| * Opt. 28: Adds LTE Downlink (Base Station) RF transmitter measurements (includes Cell ID).
| |
| * Opt. 29: Adds Bluetooth 5 transmitter measurements.
| |
| * Opt. 32: Adds EMI Pre-compliance and troubleshooting.
| |
| * Opt. B25: Adds 25 MHz real-time capture bandwidth (no cost :* Opt.).
| |
| * Opt. B40: Adds 40 MHz real-time capture bandwidth.
| |
| * Opt. B85: Adds 85 MHz real-time capture bandwidth.
| |
| * Opt. B16x: Adds 165 MHz real-time capture bandwidth.
| |
| * Opt. 50: Adds 1 MHz to 3/6.2 GHz Pre-Amplifier (RSA5103B/RSA5106B only).
| |
| * Opt. 51: Adds 1 MHz to 15/26.5 GHz Pre-Amplifier (RSA5115B/RSA5126B only).
| |
| * Opt. 53: Adds Memory, 4 GB Acquisition Memory Total.
| |
| * Opt. 54: Adds Signal survey and classification.
| |
| * Opt. 65: Adds Digital I and Q outputs.
| |
| * Opt. 66: Adds Zero-span output.
| |
| * Opt. 6566: Adds Digital I and Q outputs and Zero-span output.
| |
| * Opt. 300: Adds high performance real time DPX
| |
| * Opt. B85HD: Adds high dynamic range, 85 MHz acquisition bandwidth
| |
| * Opt. B125: Adds 125 MHz acquisition bandwidth
| |
| * Opt. B125HD: Adds high dynamic range, 125 MHz acquisition bandwidth
| |
| * Opt. B16xHD: Adds high dynamic range, 165 MHz acquisition bandwidth
| |
| * Opt. MAP: Adds mapping capability.
| |
| * Opt. PFR: Adds Precision Frequency Reference.
| |
| * Opt. PFR50: Adds Precision Frequency Reference and Internal Preamp (RSA5103B/RSA5106B only).
| |
| * Opt. WIN10REM: A removable solid-state drive. Minimum disk capacity is 480 GB. The Windows 10 operating system and instrument software is preinstalled.
| |
| * Opt. WIN10RINT: An internally mounted drive. Minimum disk capacity is 480 GB. The Windows 10 operating system and instrument software is preinstalled.
| |
| * RSA56KR: Rackmount for RSA5100A/B Series, SPECMON/B Series, and RSA6100B Series analyzers.
| |
|
| |
| ==Upgrades==
| |
| Windows 7
| |
| * RSA5BUP Option SSD: Adds an additional removable solid-state drive for units equipped with Option 56. The Windows 7 operating system and instrument software is preinstalled.
| |
| * RSA5BUP Option 56: An internal solid-state drive. The Windows 7 operating system and instrument software is preinstalled.
| |
|
| |
| Windows 10
| |
| * RSA5BUP SPARE-WIN10: Adds an additional removable solid-state hard drive. Windows 10 and instrument software pre-installed.)
| |
| * RSA5BUP WIN10REM: A removable solid-state drive. The Windows 10 operating system and instrument software is preinstalled.
| |
| * RSA5BUP WIN10INT: An internally mounted drive. The Windows 10 operating system and instrument software is preinstalled.
| |
|
| |
| ==Pictures==
| |
| <gallery>
| |
| RSA5103A.jpg
| |
| RSA5103B_1.jpg
| |
| RSA5103B_2.jpg
| |
| </gallery>
| |
|
| |
| [[Category: Spectrum Analyzers]]
| |