X381: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
No edit summary
Line 12: Line 12:
There are human-readable numbers on the disk at each rotational position.
There are human-readable numbers on the disk at each rotational position.
These number are visible outside of the enclosure.
These number are visible outside of the enclosure.
==Motorized TIME/DIV==
The TIME/DIV control is two concentric knobs.
===Outer Knob===
The outer knob is the coarse TIME/DIV control,
and goes in 1-2-5 steps from 2 sec/div to 1 μs/div.
The front panel knob rotates this rotary switch.
However, the switch can also be controlled by a motor in the plug-in.
When the coarse TIME/DIV control is rotated using the front panel knob,
the motor's gear is mechanically disengaged from the rotary switch shaft.
The rotary coarse TIME/DIV switch controls the rightmost nixie tube,
which shows the TIME/DIV units.
===Inner Knob===
The inner knob is probably a vernier TIME/DIV control.
The inner knob rotates the optical disk and a precision rotary potentiometer.
Each radial position of the disk produces a pattern of light/dark in the light pipes coming out of the disk.
The patterns encode vernier TIME/DIV values.
Each light pipe goes to a photosensor, which controls the left three decimal nixie tube.
The inner knob, like the outer knob, can be rotated by turning the front-panel knob,
but is also motor-controlled, presumably to enable automated measurement.


<gallery>
<gallery>

Revision as of 08:15, 7 February 2020

The X381 is an experimental 560-series timebase plug-in. It appears to have used a 3B1 plug-in as a starting point.

The front panel has a Nixie display which is driven by a Fairchild 9960 decoder/driver IC.

Within the X381, there is an octagonal aluminum enclosure containing a backlit disk of film that is rotated by a front panel knob. The disk functions similarly to a quadrature optical encoder, but instead of generating just two signals, it generates several signals. There are human-readable numbers on the disk at each rotational position. These number are visible outside of the enclosure.

Motorized TIME/DIV

The TIME/DIV control is two concentric knobs.

Outer Knob

The outer knob is the coarse TIME/DIV control, and goes in 1-2-5 steps from 2 sec/div to 1 μs/div. The front panel knob rotates this rotary switch. However, the switch can also be controlled by a motor in the plug-in. When the coarse TIME/DIV control is rotated using the front panel knob, the motor's gear is mechanically disengaged from the rotary switch shaft.

The rotary coarse TIME/DIV switch controls the rightmost nixie tube, which shows the TIME/DIV units.

Inner Knob

The inner knob is probably a vernier TIME/DIV control. The inner knob rotates the optical disk and a precision rotary potentiometer. Each radial position of the disk produces a pattern of light/dark in the light pipes coming out of the disk. The patterns encode vernier TIME/DIV values. Each light pipe goes to a photosensor, which controls the left three decimal nixie tube. The inner knob, like the outer knob, can be rotated by turning the front-panel knob, but is also motor-controlled, presumably to enable automated measurement.