TransEra 641-RTC: Difference between revisions

From TekWiki
Jump to navigation Jump to search
(Added pictures and some informations about an earlier revision)
(removed wrong picture)
Line 55: Line 55:
TransEra_641RTC_04.jpg|Top view of PCB
TransEra_641RTC_04.jpg|Top view of PCB
TransEra_641RTC_05.jpg|Bottom view of PCB
TransEra_641RTC_05.jpg|Bottom view of PCB
TransEra_641RTC_07.jpg
TransEra_641RTC_schematic.pdf|Schematic of revision 2
TransEra_641RTC_schematic.pdf|Schematic of revision 2
</gallery>
</gallery>

Revision as of 10:47, 4 April 2022

The TransEra 641 Real Time Clock ROM Pack (641-RTC) is a ROM pack for the 4051 microcomputer.


Command set

Command Description
CALL "TIMSET", T Sets the actual time. T must be a floating point number containing the count of seconds + fractions since the 01-01 of the current year.
The resolution is 1/128 of a second.
CALL "TIMSET",T$ Sets the actual date & time. T$ must be a string in the format "MM-DD-YY HH:MM:SS".
The time must be always given in 24h format.
CALL "TIME",T Returns the actual time. The result T is a floating point number and contains the count of seconds since 01-01 of the current year.
The resolution is 1/128 of a second.
CALL "TIME",T$ Returns the actual date & time. T$ contains a string in the format "WEK MM DD YY HH:MM:SS [AM/PM]".
The string is formatted depending on previous calls of 24HOUR or 12HOUR.
Examples:
MON 07 MAR 21 4:15:20 PM
MON 07 MAR 21 16:15:20
Remark:
As with all 4050 RTC modules the 641-RTC is not Y2K compatible. So in this example the weekday of march, 7th, 1921 is returned.
CALL "CLOCK",T$ Same as "TIME",T$ and "TIME",T
CALL "PAUSE",T Pauses the Program for T seconds. The parameter T must be an integer value.
The maximum delay is 65535 seconds (~18hours)
After the pause the program execution starts at the next line.
CALL "TIMER",T,L Starts an asynchronous timer with the delay T and jumps to line L when the timer is done.
The maximum delay is 65535 seconds (~18hours).
The timer is not retriggered automatically.
CALL "12HOUR" Sets the format of the returned time strings to 12-hour format.
This is the default time format after a power-cycle.
CALL "24HOUR" Sets the format of the returned time strings to 24-hour format.

Revisions

At least 3 revisions were released. The first version came without a battery, so all time information was lost after a powercycle. The second revision added a battery for counting the seconds within the year. But the year information was still unprotected. The manual of the TransEra 741-RTC explicitly talks about a 741-RTC and a 641-RTC with identical command set. The command set in the manual differs from the command set of the units shown on this page. So a third hardware revision of the 641 should exist.

Pictures revision 1

Pictures revision 2

Pictures revision 3

Firmware (uploaded BIN files)

File Description
TransEra-641-RTC-1984.bin (?) Original Firmware
TE-rtc-641_y2k.bin (?) Modified Firmware for Y2k compatibility