Tektronix P6023
1 kV, 10X, Adjustable Passive Probe
P6023

Compatible with 1 MΩ scope inputs

Produced from 1961 to (?)

Manuals


Manuals – Specifications – Links – Pictures

The Tektronix P6023 is a 10X, 1000 V max. scope probe with 8 MΩ input resistance.

It has variable attenuation and compensation to permit equalizing a pair of these probes on a differential amplifier. The manual refers to Type W, 10A1, and 1A7 specifically.

Versions with BNC (010-0168-00) and UHF connectors (010-0097-00) exist.

Key Specifications

Bandwidth 50 MHz
Risetime < 7 ns
Attenuation adjustable 9.75-10.25 : 1
Input impedance 7.8-8.2 MΩ // 12 pF
Compensation range 1 MΩ // 20-47 pF
CMRR Not specified
Max. input 1000 V (DC + peak AC)