The '''Tektronix P6032''' is an 850 MHz cathode-follower probe, intended for use with samplers such as the [[1S1]], [[3S1]], | The '''Tektronix P6032''' is an 850 MHz cathode-follower probe, intended for use with samplers such as the [[1S1]], [[3S1]], [[3S76]], [[4S1]], and [[4S2]]. | ||
It was designed by [[Murlan Kaufman]]. | It was designed by [[Murlan Kaufman]]. | ||
Line 13: | Line 13: | ||
It appears to be 21 mm of RG-174 cable connected to the triode's cathode at one end, and open at the other end. | It appears to be 21 mm of RG-174 cable connected to the triode's cathode at one end, and open at the other end. | ||
The circuit description in the manual describes it vaguely, saying only that, "The clipping line reduces signal aberration to a minimum." | The circuit description in the manual describes it vaguely, saying only that, "The clipping line reduces signal aberration to a minimum." | ||
{{BeginSpecs}} | |||
{{Spec | Bandwidth | 850 MHz }} | |||
{{Spec | Rise time | 0.4 ns max. }} | |||
{{Spec | Attenuation |10× to 1000× in 1-2-5 steps with supplied attenuator heads, 3× without attenuator }} | |||
{{Spec | Dynamic range | ±0.15 V × attenuation }} | |||
{{Spec | Maximum input voltage | ±0.225 V × attenuation, de-rated for CW operation for 500× and 1000× attenuator heads }} | |||
{{Spec | Input resistance | 10 MΩ with any attenuator head, 3 MΩ without attenuator head }} | |||
{{Spec | Input capacitance | 3.6 pF (10× head) to 1.3 pF (1000× head), 7 pF without attenuator head}} | |||
{{Spec | Output impedance | not specified, calibrated for 50 Ω load }} | |||
{{EndSpecs}} | |||