There are two versions of the PG506. The older version has two relays that switch a low-pass (noise) filter into the 10V and below ranges. The new version just has a capacitor across the output for these ranges.
Common failure modes: For low or no output on the 20V-up ranges, Q270, Q280 and Q290.


<gallery>
<gallery>

Revision as of 13:53, 21 January 2016

Tektronix PG506
1 MHz calibration generator
Tektronix PG506

Produced from 1974 to 1993

Manuals
(All manuals in PDF format unless noted otherwise)
Manuals – Specifications – Links – Pictures

The Tektronix PG506 is a 1 MHz calibration generator plug-in for the TM500 system.


There are two versions of the PG506. The older version has two relays that switch a low-pass (noise) filter into the 10V and below ranges. The new version just has a capacitor across the output for these ranges.

Common failure modes: For low or no output on the 20V-up ranges, Q270, Q280 and Q290.

<gallery> File:Tek pg506 left internal.JPG|PG506 Left Internal File:Tek pg506 right internal.JPG|PG506 Right Internal File:Tek pg506 late.JPG|PG506 Front File:Tek pg506a front.jpg|PG506A Front <gallery>