7S14 is a Dual Trace Delayed Sweep Sampler Plugin.
It combines a two channel sampler and is kompatible to any 7000-Mainframe and forms them to a 1GHz oszilloscope. There are button-batterie cells, acting as floating bias sources inside the sampling circuit, so the unit stopps working, it may be not defective, just check at first the voltage on the cells! There is also a integrated delay measurement function. Allowed input voltage range is only 5Vpk.
- Risetime = 350 ps (This means 1 GHz bandwith)
- Vertical deflection 2mV/DIV to 0.5V/DIV in 1,2,5 sequence
- Time base deflection factor 100 µs/DIV to 100 ps/DIV in 1,2,5 sequence
- delayed timebase
- 50 ohms input