7B53A: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
No edit summary
Line 19: Line 19:
The 7B53AN is electrically identical to he 7B53A but omits the circuits needed to drive the alphanumeric
The 7B53AN is electrically identical to he 7B53A but omits the circuits needed to drive the alphanumeric
readout system provided in 7000-series mainframes.
readout system provided in 7000-series mainframes.
The 7B53 uses the -50 V supply provided by the mainframe.


{{BeginSpecs}}
{{BeginSpecs}}

Revision as of 16:55, 15 April 2018

Template:Plugin Sidebar 2

The Tektronix 7B53A and 7B53AN is a 100 MHz dual time base plug-in for 7000-series scopes. It is similar to the 7B52 which is much more rarely found. While the 7B52 has a separate mode switch, this is integrated into the time/Div switch in the 7B53A.

The 7B53AN is electrically identical to he 7B53A but omits the circuits needed to drive the alphanumeric readout system provided in 7000-series mainframes.

The 7B53 uses the -50 V supply provided by the mainframe.

Key Specifications

Sweep rates 50 ns/Div to 5 s/Div in 1—2—5 sequence (5 ns with ×10 magnification)
Deflection 10 mV/Div, 100 mV/Div or 1 V/Div, up to 2 MHz
Sensitivity 0.3 Div or 100 mV up to 10 MHz, 1.5 Div or 500 mV up to 100 MHz
Coupling DC, AC (> 30 Hz), AC LF REJ (> 30 kHz), AC HF REJ (30 Hz — 150 kHz)
Input impedance 1 MΩ // 20 pF
Jitter < 1 ns at 75 MHz
Features
  • Dual delayed timebase
  • External trigger inputs for main and delayed
  • Display modes: Main, Intensified, Delayed, Mixed
Options
  • Option 5 for the 7B53A adds a TV Sync Separator (video trigger).

Variable control

Through an internal jumper, the front-panel variable control (red knob) can be selected to vary either the main sweep, the delayed sweep or the main sweep hold-off. See i.a. TekScope Vol. 7 No. 5, 1975 p.15+: Dave McCullough, Delayed gate aids oscilloscope digital measurements.

X-Y operation

The 7B53 supports X-Y mode by selecting the "Ampl" position on the Time/Div switch. The X signal can be picked up from a vertical plug-in via the internal trigger path or applied via the "Main Trig In or Amp In" input, as determined by the Trigger Source switch setting. Sensitivity on the external input is 100 mV/Div, which can be increased to 10 mV/DIv by selecting the x10 magnifier, or decreased to 1 V/Div by pushing the EXT÷10 button.

Prices

Year 1973 1976 1980 1984 1990
Catalog price $850 $925 $1,135 $1,515 $2,500
2015 value $4,520 $3,840 $3,250 $3,440 $4,520

Pictures