The Tektronix 2215 is a portable dual-trace 60 MHz scope from the 2000-series of low-cost analog scopes.
There is also a 2215A (same specifications as 2215 with improved CRT intensity and bandwidth limit ?)
Key Specifications
— Vertical — | |
Deflection | 2 mV to 10 V per division, 1-2-5 |
Rise time | < 5.8 ns (calculated) |
Bandwidth | DC to >60 MHz, 20 mV/Div to 10 V/Div, 0 °C to +40 °C; >50 MHz in 2 mV/Div to 10 mV/Div ranges or from +40 °C to +50 °C |
Input impedance | 1 MΩ ±2% // 30 ±3 pF |
Maximum Safe Input Voltage | 400 V (dc + peak AC) or 800 Vp-p AC to 1 kHz or less |
CMRR | At least 10:1 at 10 MHz |
— Horizontal — | |
Timebase | 50 ns/Div to 500 ms/Div, 1-2-5, ×10 magnifier, i.e. down to 5 ns/Div |
— Trigger — | |
Sensitivity | 0.4 Div internal / 50 mV external up to 2 MHz; 1.5 Div internal / 250 mV external up to 60 MHz |
AC coupled trigger | ≤10 Hz (-3 dB) |
External trigger input | max. 400 V (DC+peak AC) or 800 Vp-p AC to 1kHz or less; impedance 1 MΩ ±2% // 30 ±3 pF |
Trigger modes | Auto, Norm, TV Field |
— Miscellaneous — | |
Features |
|
Z axis | input (intensity); DC to 5 MHz |
CRT | display area : 80 × 100 mm² |
Weight | 6.1 kg; 7.6 kg with front panel cover, accessories and pouch |
Dimensions | With feet and handle: 137 x 361 x 511 mm³ |