Revision as of 13:03, 13 October 2018
The 067-0077-00 is a square wave calibrator for checking the calibrator circuits in scopes. It contains a precision voltage divider which it uses to get voltages in the standard 1-2-5 sequence between 0.2 mV and 100 V. An internal relay switches between between the divided reference voltage and an external unknown voltage which is applied to the 067-0077-00.