The Tektronix PG506 is a 1 MHz calibration generator plug-in for the TM500 system.
There are (at least) two versions of the PG506. The older version has two relays that switch a low-pass (noise) filter into the 10 V and below ranges. The new version just has a capacitor across the output for these ranges.
Common failure modes: In case of low or no output on the 20 V and above ranges, check Q270, Q280 and Q290.
-
PG506 Left Internal
-
PG506 Left Internal
-
PG506 Right Internal
-
PG506 Right Internal
-
PG506 Front
-
PG506A Front
-
Newer version without filter relays
-
PG506A
-
PG506A output waveform