{{Spec | Acquisition Modes| Peak Detect, Sample, Average, Single Sequence } | |||
{{Spec | Trigger Types| Edge (rising or falling), Video (NTSC, PAL, SECAM), Pulse Width (or Glitch) }} | |||
{{Spec | Trigger Modes| Auto, Normal, Single Sequence }} | |||
{{Spec | Trigger Source| CH1, CH2, Ext, Ext/5, AC Line }} | |||
{{Spec | Trigger View| Displays trigger signal while trigger view button is depressed }} | |||
{{Spec | Trigger Signal Frequency Readout| Provides a frequency readout of the trigger source }} | |||
{{Spec | Cursors| Time, Voltage, Measurements: [Δ]T, 1/[Δ]T (frequency), [Δ]V }} | |||
{{Spec | Automatic Waveform Measurements| Period, Frequency, +Width, -Width, Rise Time, Fall Time, Max, Min, Peak-to-Peak, Mean, Cycle RMS }} | |||
{{Spec | Waveform Processing| Operators (Add, Subtract, FFT); FFT (Windows: Hanning, Flat Top, Rectangular; 2048 sample points; Autoset Menu (Single-button, automatic setup of all channels for vertical, horizontal, and trigger systems with undo autoset) }} | |||
{{Spec | Autoset Menu| Square Wave (Single-cycle, Multi-cycle, Rising or Falling Edge); Sine Wave (Single-cycle, Multi-cycle, FFT Spectrum); Video (NTSC, PAL, SECAM) Field: All, Odd or Even Line:All or Selective Line Number }} | |||
{{Spec | Interface| Centronics type parallel, RS-232, GPIB, Compact Flash Memory }} | |||
{{Spec | Probes| Two [[P2220]] 200 MHz ×10 to x1 probes [[BNC connector]] }} | |||
{{EndSpecs}} | {{EndSpecs}} | ||
Revision as of 15:23, 24 May 2019
The Tektronix TDS1012 is a dual-channel, 100 MHz, 1 GS/s digital scope with a monochrome LCD screen.
Key Specifications
{{Spec | Acquisition Modes| Peak Detect, Sample, Average, Single Sequence }Display (1/4 VGA LCD) | Mono |
---|---|
Bandwidth | 100 MHz; Bandwidth is 20 MHz at 2 mV/div |
Channels | 2 |
Ext Trigger Input | Present |
Sample Rate on each channel | 1.0 GS/s |
Record Length | 2.5 K points |
Vertical Resolution | 8-bits |
Vertical Sensitivity | 2 mV to 5 V/div with calibrated fine adjustment |
DC Vertical Accuracy | ±3% |
Vertical Zoom | Vertical expand or compress a live or stopped waveform |
Max Imput Voltage | 300 VRMS CAT II; derated at 20 dB/decade above 100 kHz to 13 Vp-p AC at 3 MHz and above |
Position Range | 2 mV to 200 mV/div ±2 V; >200 mV to 5 V/div ±50 V |
BW Limit | 20 MHz |
Input Coupling | AC, DC, GND |
Input Impedance | 1 MΩ in parallel with 20 pF |
Time Base Range | 5 ns to 50 s/div |
Time Base Accuracy | 50 ppm |
Horizontal Zoom | Horizontal expand or compress a live or stopped waveform |
Trigger Types | Edge (rising or falling), Video (NTSC, PAL, SECAM), Pulse Width (or Glitch) |
Trigger Modes | Auto, Normal, Single Sequence |
Trigger Source | CH1, CH2, Ext, Ext/5, AC Line |
Trigger View | Displays trigger signal while trigger view button is depressed |
Trigger Signal Frequency Readout | Provides a frequency readout of the trigger source |
Cursors | Time, Voltage, Measurements: [Δ]T, 1/[Δ]T (frequency), [Δ]V |
Automatic Waveform Measurements | Period, Frequency, +Width, -Width, Rise Time, Fall Time, Max, Min, Peak-to-Peak, Mean, Cycle RMS |
Waveform Processing | Operators (Add, Subtract, FFT); FFT (Windows: Hanning, Flat Top, Rectangular; 2048 sample points; Autoset Menu (Single-button, automatic setup of all channels for vertical, horizontal, and trigger systems with undo autoset) |
Autoset Menu | Square Wave (Single-cycle, Multi-cycle, Rising or Falling Edge); Sine Wave (Single-cycle, Multi-cycle, FFT Spectrum); Video (NTSC, PAL, SECAM) Field: All, Odd or Even Line:All or Selective Line Number |
Interface | Centronics type parallel, RS-232, GPIB, Compact Flash Memory |