2335: Difference between revisions
No edit summary |
No edit summary |
||
Line 7: | Line 7: | ||
summary=Ruggedized 100 MHz dual trace scope | | summary=Ruggedized 100 MHz dual trace scope | | ||
manuals= | manuals= | ||
Need Operators and Service manuals | |||
* [[Media:TEK 2335 Instruction.pdf| Tektronix 2335 Instruction Manual ]] (PDF) | * [[Media:TEK 2335 Instruction.pdf| Tektronix 2335 Instruction Manual ]] (PDF) | ||
* [[Media:Tektronix-2300-Series_Brochure.pdf| Tektronix 2300 Series Brochure ]] (PDF) | * [[Media:Tektronix-2300-Series_Brochure.pdf| Tektronix 2300 Series Brochure ]] (PDF) | ||
* [[Media:070-4115-00.pdf|Tektronix 2335 Instruction Manual ]] (PDF, OCR, bad-OCR) | * [[Media:070-4115-00.pdf|Tektronix 2335 Instruction Manual ]] (PDF, OCR, bad-OCR) |
Revision as of 20:16, 17 August 2019
The Tektronix 2335 is a ruggedized portable dual-channel, 100 MHz analog scope. An External trigger input on front and External Z-Axis connector at the rear round out its connectivity.
Vertical controls were by way of calibrated deflection factors on CH 1 or CH 2 inputs through AC, DC, or GND coupling. The vertical mode selections are CH 1, BOTH, CH 2, ADD, ALT, CHOP (500 kHz), TRIG VIEW, or BW LIMIT (20 MHz). Horizontal deflection is controlled by either the calibrated A or B Sweep Generators, or Alternate between the two of the A, and B Delayed Sweep.
Trigger modes may be one of four modes: Single Sweep Reset, P-P Auto-TV Line, Normal, and TV Field. Trigger sources can be Internal, Line, or External, and can be controlled by amplitude level and slope type. The Internal signal source(s) is(are) from signals applied to channels 1 or 2, or based on what Vertical Mode selected.
Key Specifications
Bandwidth and Channels | 100 MHz in a 1, 2, 5 sequence; Bandwidth is at least 90 MHz at 2 mV/div; 2 Channels |
---|---|
Deflection Factor | CH 1, 2: 5 mV/div to 5 V/div, all ±2%; Variable control can increase sensitivity to at least 2 mV/div. |
Input Impedance | 1 MΩ ±2% and 20 pF ±2 pF |
Maximum Input Voltage | 400 V (DC + peak AC) or 500 V (p-p ac at ≤ 1 kHz) |
Sweep Speeds | A Time Base: 0.5 s/div to 50ns/div; B Time Base: 50 ms/div to 50 ns/div; A and B X10 magnifier extends max sweep to 5 ns/div |
Trigger Source | INT (CH1, 2), LINE, EXT (AC, DC, DC ÷ 10) |
Probes | Two P6108A 100 MHz X10 probes, BNC connector with a readout pin |
Power | 40 W max, 90 − 250 VAC, 48 − 440 Hz |
Links
- TekScope Vol. 13 No. 2, June 1981 p.10+: Three New Portable Oscilloscopes Designed for Field Service Use