The Tektronix 105 is a 25 Hz to 1 MHz square wave generator. It is all tube.
The 105 has a d'Arsonval meter on its front panel indicating the current frequency. The frequency meter works on the principle of moving a constant amount of charge per cycle, integrating this charge into a current, and measuring the current.
The output is generated at the plates of three 6AG7 triodes that run in parallel. It was designed by Howard Vollum and Charles Sanford.
Specifications
- Frequency range: 25 Hz to 1 MHz
- Rise and fall time (10% to 90%): 20 nanoseconds
- Amplitude range (600-ohm internal load only): 10 V to 100 V peak-to-peak
- Amplitude range (93-ohm external load): 1.5 V to 15 V peak-to-peak
- Power consumption: 250 watts
- Weight: 35 pounds
Manuals
- Tektronix 105 Manual (PDF)
- Tektronix 105 Manual (Djvu)
- Tektronix 105 Field Recalibration Procedure (PDF)
Pictures
-
105 front
-
Early style of 105 with blocky meter
-
-
-
-
manual
-
powered on
-
internal view, tube side
-
right interior
-
output section detail
-
output waveform of 105
-
Block diagram
-
Power supply schematic
-
Generator schematic
-
Early Tek 105 with horizontal case