P6108: Difference between revisions
Jump to navigation
Jump to search
(Fleshed out, added specs section) |
mNo edit summary |
||
Line 17: | Line 17: | ||
{{BeginSpecs}} | {{BeginSpecs}} | ||
{{Spec | Attenuation | 10 × ±3% with 1 MΩ ±2% scope input }} | {{Spec | Attenuation | 10 × ±3% with 1 MΩ ±2% scope input }} | ||
{{Spec | Maximum Voltage | 500 V DC + peak AC, derated with frequency }} | |||
{{Spec | Compensation range | 15 pF to 47 pF }} | {{Spec | Compensation range | 15 pF to 47 pF }} | ||
{{Spec | Bandwidth | 100 MHz (95 MHz for 3 meter cable) }} | {{Spec | Bandwidth | 100 MHz (95 MHz for 3 meter cable) }} |
Revision as of 14:05, 7 December 2021
The Tektronix P6108 is a passive 100 MHz, ×10, miniature modular probe for 1 MΩ scope inputs. It appears to be the same as the P6105, but without the readout encoding pin. It has a BNC connector.
Key Specifications
Attenuation | 10 × ±3% with 1 MΩ ±2% scope input |
---|---|
Maximum Voltage | 500 V DC + peak AC, derated with frequency |
Compensation range | 15 pF to 47 pF |
Bandwidth | 100 MHz (95 MHz for 3 meter cable) |
Input capacitance | 10.5 pF (1 m), 13 pF (2 m), 15.5 pF (3 m) |
Pictures
-
1 m (blue) P6108
-
2 m (yellow) P6108
-
2 m (yellow) P6108
-
2 m (yellow) P6108