Revision as of 14:05, 7 December 2021

Tektronix P6108
Passive 100 MHz, ×10 probe
Tektronix P6108

Compatible with 1 MΩ scope inputs

Produced from 1977 to (?)

Manuals


Manuals – Specifications – Links – Pictures

The Tektronix P6108 is a passive 100 MHz, ×10, miniature modular probe for 1 MΩ scope inputs. It appears to be the same as the P6105, but without the readout encoding pin. It has a BNC connector.

Key Specifications

Attenuation 10 × ±3% with 1 MΩ ±2% scope input
Maximum Voltage 500 V DC + peak AC, derated with frequency
Compensation range 15 pF to 47 pF
Bandwidth 100 MHz (95 MHz for 3 meter cable)
Input capacitance 10.5 pF (1 m), 13 pF (2 m), 15.5 pF (3 m)

Pictures