==Options==
==Options==
* J16 Option 1 - 180-272 VAC 50 to 400 Hz operation.
* Option 1 - 230 VAC 50 operation (battery charger)
* J16 Option 3 - 115 VAC Power Supply
* Option 2 - Metric Readout
* J16 Option 4 - 230 VAC Power Supply
* Option 3 - 115 VAC Power Supply
* Option 4 - 230 VAC Power Supply
* Option 07 - BCD/Analog output (25 pin connector on top of J16)
* Option 07 - BCD/Analog output (25 pin connector on top of J16)


==Accessories==
==Accessories==
Luminance Probes:
* 012-0414-00 - 42-Inch Probe Extender Cable - Connects between the J16 and probe.
* [[J6503]]
* 016-0527-00 - Filter Holder - Mounts one-inch diameter filters, of up to 3/8-inch thickness, to probes.
* [[J6523]]
* 016-0539-00 - Spare Battery Pack
* 119-0404-00 - AC Power Supply - Allows J16 to be used without batteries.


Illuminance Probes:
Illuminance Probes:
Line 55: Line 57:
* [[J6502]]
* [[J6502]]
* [[J6512]]
* [[J6512]]
Luminance Probes:
* [[J6503]]
* [[J6523]]


Uncorrected Probes:
Uncorrected Probes:

Revision as of 10:08, 30 August 2022

Tektronix J16
Tektronix J16 Digital Photometer/Radiometer

Produced from (1972) to (?)

Manuals
Manuals – Specifications – Links – Pictures


The Tektronix J16 is a digital photometer. The instrument could be configured to either use rechargeable batteries or line voltage (119-0404-00).

Key Specifications

Measurement Range - J6501 or J6511 Illuminance Probes 0.001 to 1,999 foot candles
Measurement Range - J6502 or J6512 Irradiance Probes 0.001 to 1,999 μW/cm²
Measurement Range - J6503 or J6513 Luminance Probes 0.1 to 199,900 lamberts
Resolution - Illuminance Probes 0.0001 foot candle
Resolution - Irradiance Probes 0.0001 μW/cm²
Resolution - Luminance Probes 0.01 lamberts
System Accuracy Maximum absolute uncertainty ±5%, ±1 digit, on any range; uncertainty of linearity is ±2% or less
Temperature Operating -15 °C to +40 °C (+5 °F to +104 °F)
Temperature Storage -55 °C to +75 °C (-67 °F to +167 °F)
Altitude Operating 15,000 feet
Altitude Storage 50,000 feet
Humidity 5 cycles (120 hours) to 95% relative humidity, referenced to MIL-E-16400F
Weight 3.25 pounds (1.5 Kg)
Dimensions Height: 2.375 inches (6 cm), Width: 4.625 inches (12.3 cm), Depth: 8 inches (20.3 cm)

Options

  • Option 1 - 230 VAC 50 operation (battery charger)
  • Option 2 - Metric Readout
  • Option 3 - 115 VAC Power Supply
  • Option 4 - 230 VAC Power Supply
  • Option 07 - BCD/Analog output (25 pin connector on top of J16)

Accessories

  • 012-0414-00 - 42-Inch Probe Extender Cable - Connects between the J16 and probe.
  • 016-0527-00 - Filter Holder - Mounts one-inch diameter filters, of up to 3/8-inch thickness, to probes.
  • 016-0539-00 - Spare Battery Pack
  • 119-0404-00 - AC Power Supply - Allows J16 to be used without batteries.

Illuminance Probes:

Irradiance Probes:

Luminance Probes:

Uncorrected Probes:

LED Probe:


Links

Pictures