P6016: Difference between revisions

From TekWiki
Jump to navigation Jump to search
m (added passive termination part #, plus minor wording for clarity)
No edit summary
Line 5: Line 5:
|image=Tek-p6016.jpg
|image=Tek-p6016.jpg
|caption=P6016 Probe
|caption=P6016 Probe
|for=131
|for=Type 131
|introduced=1960
|introduced=1960
|discontinued=(?)
|discontinued=(?)
Line 14: Line 14:
[[File:Tek 131 front.jpg|thumb|250px|right|Type 131 Current Probe Amplifier for P6016]]
[[File:Tek 131 front.jpg|thumb|250px|right|Type 131 Current Probe Amplifier for P6016]]


The '''Tektronix P6016''' is a passive current probe for oscilloscopes. It must be used with either the 011-028 Passive Termination or the [[131|Type 131 Current Probe Amplifier]]. It has a 125:1 current transformer ratio.
The '''Tektronix P6016''' is a 125-turn AC current probe for oscilloscopes. It must be used with either the 011-028 passive termination or the [[131|Type 131 Current Probe Amplifier]].


{{BeginSpecs}}
{{BeginSpecs}}
Line 20: Line 20:
{{Spec | DC saturation | 0.5 A }}
{{Spec | DC saturation | 0.5 A }}


{{SpecGroup | With 011-028 Passive Termination }}
{{SpecGroup | With the 011-028 Passive Termination }}
{{Spec | Sensitivity | 2 mA/mV or 10 mA/mV selectable }}
{{Spec | Sensitivity | 2 mA/mV or 10 mA/mV selectable }}
{{Spec | Rise time | 18 ns (eq. 20 MHz -3 dB) }}
{{Spec | Rise time | 18 ns (eq. 20 MHz -3 dB) }}
Line 26: Line 26:
{{Spec | Delay time | 12 ns typ. }}
{{Spec | Delay time | 12 ns typ. }}


{{SpecGroup | With [[131]] Current Probe Amplifier }}
{{SpecGroup | With a Type [[131]] Current Probe Amplifier }}
{{Spec | Sensitivity | 1 mA/Div to 1 A/Div, 1-2-5 }}
{{Spec | Sensitivity | 1 mA/Div to 1 A/Div, 1-2-5 }}
{{Spec | Noise | 0.1 mA<sub>p-p</sub> }}
{{Spec | Noise | 0.1 mA<sub>p-p</sub> }}

Revision as of 21:45, 6 March 2023

Tektronix P6016
Oscilloscope Current Probe
P6016 Probe

Compatible with Type 131

Produced from 1960 to (?)

Manuals


Manuals – Specifications – Links – Pictures
011-028 Passive Termination for P6016
Type 131 Current Probe Amplifier for P6016

The Tektronix P6016 is a 125-turn AC current probe for oscilloscopes. It must be used with either the 011-028 passive termination or the Type 131 Current Probe Amplifier.

Key Specifications

Maximum current 15 Ap-p
DC saturation 0.5 A
     — With the 011-028 Passive Termination
Sensitivity 2 mA/mV or 10 mA/mV selectable
Rise time 18 ns (eq. 20 MHz -3 dB)
Low frequency -3 dB point Switchable between 850 Hz at 2 mA/mV or 230 Hz at 10 mA/mV
Delay time 12 ns typ.
     — With a Type 131 Current Probe Amplifier
Sensitivity 1 mA/Div to 1 A/Div, 1-2-5
Noise 0.1 mAp-p
Rise time 20 ns (eq. 17 MHz -3 dB)
Low frequency -3 dB point 50 Hz
Delay time 32 ns typ.

Pictures