3M1: Difference between revisions
m (Add categories in the hope that this will let 3M1 show up in 3-series plugins) |
(Create 3M1 page, moving content from numbered page, organizing, and adding photos) Tag: Removed redirect |
||
Line 1: | Line 1: | ||
{{Plugin Sidebar | |||
|manufacturer=Tektronix | |||
|series=560-series plugins | |||
|type=067-0500-00 | |||
|summary=calibration fixture | |||
|image=3M1_F.JPG | |||
|caption=3M1 Front | |||
|introduced=(?) | |||
|discontinued=(?) | |||
|designers= | |||
|manuals= | |||
* [[Media:062-0806-00.pdf|Tektronix 067-0500-00 Manual (-00)]] (OCR) | |||
* [[Media:062-0806-01.pdf|Tektronix 067-0500-00 Manual (-01)]] | |||
}} | |||
The '''Tektronix 3M1''' (first designated the 067-050, then the 067-0050-00) is a calibration fixture for adjusting the normalizing capacitor behind the plug-in connector in [[560-series scopes]]. | |||
It consists of a Schmitt trigger that is driven from a single-ended input coming from a BNC connector on the front panel. | |||
The Schmitt trigger produces balanced output signals with controlled source impedance. | |||
The normalizing capacitor is adjusted using a procedure similar to adjusting probe compensation. | |||
When adjusted correctly, the voltage division ratio formed by the plug-in's output impedance and the mainframe's input impedance should be a real value which does not change across the specified frequency range of the scope. | |||
After the scope is normalized using the 3M1, other plug-ins can be adjusted to produce clean transient response in the normalized scope. | |||
==067-050== | |||
<gallery> | |||
067-500 1a.jpg | |||
067-500 3.jpg | |||
067-500 5a.jpg | |||
</gallery> | |||
==067-0050-00== | |||
<gallery> | |||
067-0500-00_front.jpg | |||
067-0500-00_schem.jpg | |||
067-0500-00_insides.jpg | |||
</gallery> | |||
==3M1== | |||
<gallery> | |||
3M1_F.JPG | 3M1 Front | |||
3M1_PCB.JPG | 3M1 Circuit Board (note added resistor) | |||
3M1_SCH.JPG | 3M1 Schematic | |||
</gallery> | |||
[[Category:Calibration fixtures]] | [[Category:Calibration fixtures]] | ||
[[Category:560 series plugins]] | [[Category:560 series plugins]] |
Revision as of 09:16, 22 September 2023
The Tektronix 3M1 (first designated the 067-050, then the 067-0050-00) is a calibration fixture for adjusting the normalizing capacitor behind the plug-in connector in 560-series scopes.
It consists of a Schmitt trigger that is driven from a single-ended input coming from a BNC connector on the front panel. The Schmitt trigger produces balanced output signals with controlled source impedance. The normalizing capacitor is adjusted using a procedure similar to adjusting probe compensation. When adjusted correctly, the voltage division ratio formed by the plug-in's output impedance and the mainframe's input impedance should be a real value which does not change across the specified frequency range of the scope. After the scope is normalized using the 3M1, other plug-ins can be adjusted to produce clean transient response in the normalized scope.
067-050
067-0050-00
3M1
-
3M1 Front
-
3M1 Circuit Board (note added resistor)
-
3M1 Schematic