P6443
The Tektronix P6443 TTL-threshold probe can be used with the 1230, 1225 and 1220 Logic Analyzers.
It is a 16-channel data acquisition probe with 4 clocks, 2 qualifier and 2 external trigger inputs.
- Note from operators manual:
You cannot mix P6442 probes with P6443 or P6444 probes to take an acquisition. If you acquire data on P6442 probes at the same time you try to sample data on P6443/P6444 probes, the acquired data from the P6443/P6444 probes will be invalid.
Links
Pictures
- please add