2230
The Tektronix 2230 is a portable 100 MHz, dual-channel combination analog / digital storage scope, sister model of 2220 and 2221.
It has both an analog mode and a digital mode. In the digital storage mode, up to three waveform sets (CH 1 and/or CH 2) may be stored in a save ref. memory and recalled for display at a later time.
The 2230 features alphanumeric CRT readout of many of the front panel controls. It has a DB-9 auxiliary connector on the right side providing an external clock input as well as an output for an analog X-Y plotter to make permanent copies of the display. This feature can be accessed through the "Mem select" menu.
Some Firmware versions have a diagnostics menu with the Tektronix logo and wizard image.
The Cursor knob is prone to failure. It becomes jittery and will not scroll properly.
Key Specifications
— Vertical — | |
Input impedance | 1 MΩ // 20 pF |
Maximum Safe Input Voltage | 400 V (dc + peak AC) or 800 Vp-p AC |
CMRR | At least 10:1 at 10 MHz |
— Horizontal — | |
Timebase A | 50 ns/Div to 0.5 s/Div, 1-2-5, x10 magnifier, i.e. down to 5 ns/Div. In "Store" mode lower sweep speeds up to 5 s/Div are available |
Timebase B | 50 ns/Div to 5 s/Div, 1-2-5, x10 magnifier, i.e. down to 5 ns/Div |
Bandwidth | 100 MHz (analog) |
Sampling rate | 20 MS/s |
Record length | 1K or 4K samples (single channel), optional 26K |
Z axis | input (intensity); DC to 20 MHz, maximum safe input 30V (dc + peak ac) Input resistance about 10kΩ |
CRT | display area : 8 × 10 cm² |
Dimensions | With feet and handle: 137 x 361 x 511 mm³ |
Features |
|
please add
Links
Pictures
-
-
-
-
-
-
2230A Signal Input Board
-
2230 interface board
-
upper most board