The '''Tektronix 11401''' is a digitizing scope with three plugins accepting [[:Category:11000 series plugins|11000-series plugins]] and [[7000-series plug-ins]].
The '''Tektronix 11401''' is a digitizing scope with three plugins accepting [[:Category:11000 series plugins|11000-series plugins]] and [[7000-series plug-ins]].


Using random equivalent time sampling, it can acquire up to eight channels at 300 MHz, six channels at 600 MHz, or up to 3 channels at 1 GHz.  
<!-- Using random equivalent time sampling, it can acquire up to eight channels at 300 MHz, six channels at 600 MHz, or up to 3 channels at 1 GHz. -->
The 11401 mainframe uses equivalent time sampling at a rate of 20MHz (20Msps).
Each sample has 10 bits of resolution.
It is capable of displaying eight separate 10 bit resolution traces at one time.
The mainframe is fully remotely programmable over RS-232 or GPIB.
 
This mainframe accepts up to three plugins with differing numbers of channels and bandwidths.
For example, each [[11A52]] plugin allows two inputs at 500MHz bandwidth (50 ohm only input impedance).
The [[11A34]] plugin allows four inputs at 300MHz bandwidth, and the [[11A32]] allows two channels at 300MHz.
Three 11A34 plugins then allow up to 12 channels of information,
but the mainframe limits the number displayed at any one time to eight.
The other four channels may still be used for triggering.
The [[11402]] and (later) [[11403]] and [[DSA600]] mainframes allow up to 1GHz of bandwidth
with an [[11A71]] (one 50 ohm input) or two 50 ohm inputs in the (later) [[11A72]].
 
Resolution is up to 10 ps horizontal and 10 bits vertical, with 10,240 points of memory.  