647A: Difference between revisions

786 bytes added ,  6 June 2019
no edit summary
No edit summary
No edit summary
Line 20: Line 20:
The [[067-0544-00]] is a calibration plug-in for the 647A.
The [[067-0544-00]] is a calibration plug-in for the 647A.


{{MissingSpecs}}
 
{{BeginSpecs}}
{{Spec | Bandwidth | DC to 100 MHz (≤ 3 dB) with [[10A2A|Type 10A2A plug-in]]  }}
{{Spec | Rise time | 3.5 ns }}
{{Spec | Line Voltage | 108/115/122/216/235/244 V<sub>AC</sub> ±10%,selected via primary voltage selector and voltage range selector switches, 50 Hz to 60 Hz. }}
{{Spec | Thermal Protection | Automatic resetting thermal cutout, in case internal temperature exceeds safe operating level }}
{{Spec | Power Consumption | 185W with [[10A2]] & [[11B2]]  plug-in }}
{{Spec | Cooling (only Rack-Variant)  | AC Fan }}
{{Spec | Accelerating Potential | 14 kV}}
{{Spec | Screen Area | 6 cm × 10 cm}}
{{Spec | Operating Temperature  | -30 C° to +65 C°}}
{{Spec | Construction  | Aluminum alloy chassis. Anodized front panel}}
{{Spec | Weight| 40.5 lbs / 18.4 kg }}
 
{{EndSpecs}}


==Internals==
==Internals==
1,082

edits