3B1

From TekWiki
Revision as of 18:26, 19 May 2012 by Kurt (talk | contribs)
Jump to navigation Jump to search

The Tektronix 3B1 is a timebase plug-in introduced in 1962 for 560-series scopes. 10MHz is is the maximum trigger frequency. The calibrated sweep rates go from 1 sec/div to 500 nsec/div. There is a switch that enables 5X horizontal magnification, which makes the fastest sweep 100 nsec/div. The 3B1 has a delayed sweep and a regular sweep. The 3B1 uses vacuum tubes, bipolar junction transistors, and tunnel diodes.

The trigger input goes through the int/ext switch and then the ac/dc coupling switch, and then a 7895 cathode follower. The output of the cathode follower drives one base of a 2N2207 PNP differential amplifier which has a tunnel diode in the collector load. The tunnel diode generates pulses when it switches back and forth between its two stable voltages, which are capacitively coupled to a 2N2501 NPN common emitter amplifier.