PS503A Manual

There is an error in the circuit drawing: All amplifiers are connected to +5 V or -5 V. In fact they are connected to the +6.2 V or -6.2 V circuit.

PS503A: Instable Output/Output voltage is decreasing with time

The output is instable (±100 mV) and is decreasing with time. The faulty part was C34 (4.7 µF/50 V). C34 stabilises the reference voltage. Measuring C34 with an RLC-meter shows no fault: 5.0 µF and a serial resistance of 5 Ω. The faulty behaviour of C34 can only be seen by applying a DC voltage (see picture).

C34 is shorted by the output-on button. So, replacing C34 with a tantalum capacitor is not recommended.