067-0502-00: Difference between revisions

3,223 bytes added ,  15 November 2023
m
Capitolize sidebar summary
No edit summary
m (Capitolize sidebar summary)
 
(23 intermediate revisions by 4 users not shown)
Line 1: Line 1:
The Tektronix 067-0502-00 is an instrument designed for calibrating oscilloscope calibrators.
{{Instrument Sidebar
It is very similar to the [[067-0502-01]]. What are the differences?
|manufacturer=Tektronix
|model=067-0502-00
|class=Signal generator
|series=
|summary=Amplitude Calibrator
|image=067-0502-00 front.jpg
|caption=Tektronix 067-0502-00
|introduced=(?)
|discontinued=(?)
|designers=
|manuals=
* [[Media:062-0808-00.pdf|Tektronix 067-0502-00 Manual]] (PDF)
* [[Media:Tek 067-0502-00.pdf|Tektronix 067-0502-00 Manual]] (PDF, OCR)
}}
The '''Tektronix 067-0502-00''' is an instrument designed for calibrating oscilloscope calibrators.
It is very similar to the [[067-0502-01]].
The 067-0502-00 replaced the [[067-0077-00]].


[[List of manuals that are needed|Manual needed.]]
{{BeginSpecs}}
{{Spec | Output | DC+, DC-, Squarewave}}
{{Spec | Amplitude range | 0.2 mV to 100 V in 1−2−5 sequence, 5 mA in current loop}}
{{Spec | Amplitude accuracy | Within 0.25% into 1 MΩ load}}
{{Spec | Squarewave repetition rate | 1 kHz within 20% }}
{{Spec | Maximum input voltage | 100 V }}
{{Spec | 100x Amplifier gain accuracy | ±1% }}
{{Spec | 100x Amplifier risetime | < 35  μs }}
{{Spec | 100x Amplifier output range | ≥ ±20 V, ±5 mA }}
{{Spec | 100x Amplifier Output resistance | approx. 250 Ω}}
{{EndSpecs}}


==Comparison with 067-0502-01==
Sherman Foy contributed the following information:
<blockquote>
TekWiki asks the question: What is the difference? I have both units and have done an extensive review.
Looking at the front panels [TNX 4 pix] of the –00 & the –01, it seems that the –01 dropped the × 100 Amplifier section. 
The front panel is re-laid out, but what remains seems to be identical to the corresponding sections from the –00. 
In other words, the –00 provides a superset of the functionality of the -01.
Note that the –00 transformer [T310] has 6 windings and the –01 transformer [also T310] has 5 windings. 
Some currents are different, as indicated.
I have made my own notes for the project of working on the two.
Using the schematics for organization, I arrived at the following table. 
I am using a re-organization of the sheets, the block diagram of the –00 and this table:
{| class="wikitable"
|-
! scope="col"| Section
! scope="col"| -00
! scope="col"| -01
! scope="col"| Sheet in -00
! scope="col"| Sheet in -01
! scope="col"| Sheet in proposed consolidated drawing set
|-
| Square Wave calibrator
| Used in both
| Used in both
| 1
| 1
| [s/b 1]
|-
| × 100 Amplifier
| Used in -00
| Deleted in -01
| 2
| --
| [s/b 2]
|-
| Power Supply
| -00 has more sections
| Than –01
| 3
| 2
| [s/b 3A for -00 & 3B for -01]
|-
| T310
| P/N 120-0442-00
| P/N 120-0615-00
| 3
| 2
| 3A/3B
|-
| High voltage, B+
| 285 V<sub>RMS</sub>, 35 mA 300 V<sub>DC</sub>, 225 V<sub>DC</sub> &amp; 100 V<sub>DC</sub>
| 125 V<sub>RMS</sub>, 2 mA 100 V<sub>DC</sub> only
| 3
| 2
| 3A/3B
|-
| 6.3 V<sub>AC</sub> (Chopper)
| Used in -00
| Used in -01, noted as 1.84 A
| 3
| 2
| 3A/3B
|-
| 100 V<sub>RMS</sub> (-100 V<sub>DC</sub>)
| Used in -00, 40 mA
| Used in -01, 31 mA
| 3
| 2
| 3A/3B
|-
| 6.3 V<sub>AC</sub> (MV 6DJ8)
| Used in -00
| Used in -01
| 3
| 2
| 3A/3B
|-
| 330 V<sub>RMS</sub> (Floating Supply)
| Used in -00
| Used in -01
| 3
| 2
| 3A/3B
|-
| 20 V<sub>RMS</sub> (× 100 Filaments)
| Used in -00
| Not used in –01 T310
| 3
| 2
| 3A/3B
|-
| Floating power supply
| Used in both; drives Square Wave MV
| Used in both; drives Square Wave MV
| 4
| 3
| [s/b 4]
|}
</blockquote>
==Pictures==
<gallery>
<gallery>
Image:067-0502-00.JPG
067-0502-00 front.jpg
067-0502-00.JPG
</gallery>
</gallery>
[[Category:Calibration fixtures]]
[[Category:Amplitude Calibrators]]
1,325