The '''Tektronix 067-0502-01''' is an instrument that can be used to produce a reference rectangle
[[File:Tek 067-0502-01.JPG | thumb | 350px |right]]
The '''Tektronix 067-0502-01Amplitude Calibrator and Comparator''' is an instrument that can be used to produce a reference rectangle
voltage or current waveform and/or to compare an external unknown input with an internal or  
voltage or current waveform and/or to compare an external unknown input with an internal or  
external reference.  The comparison is performed using an [[Airpax A175]] chopper to switch
external reference.   
 
The comparison is performed using an [[Airpax A175]] chopper to switch
between the two voltages that are being compared.  The resulting output is a rectangular
between the two voltages that are being compared.  The resulting output is a rectangular
waveform with amplitude equal to the difference of two voltages.  It can be  
waveform with amplitude equal to the difference of two voltages.  It can be  
Line 18: Line 21:
under test for optimal match with reference.  However, if the objective of the calibration  
under test for optimal match with reference.  However, if the objective of the calibration  
is to provide assurance that the error is less than some specific value, then the gain of the
is to provide assurance that the error is less than some specific value, then the gain of the
preamplifier and oscilloscope matters.  Still, the gain of the preamp and oscilloscope only affect the accuracy of the tolerance,
preamplifier and oscilloscope matters.  Still, the gain of the preamp and oscilloscope only  
which is typically around 10%, (e.g., +/- 0.01% or +/- 0.3%).
affect the accuracy of the tolerance, which is typically around 10%, (e.g., +/- 0.01% or +/- 0.3%).


See the [[067-0502-00]] page for a comparison of the -00 and -01 models.
See the [[067-0502-00]] page for a comparison of the -00 and -01 models.
Line 32: Line 35:


<gallery>
<gallery>
File:Tek 067-0502-01.JPG|067-0502-01
Tek 067-0502-01.JPG|067-0502-01
Image:067-0502-01 schem.png|067-0502-01 Schematic
067-0502-01 schem.png|067-0502-01 Schematic
File:Tek 067-0502.JPG|067-0502
Tek 067-0502.JPG|067-0502
</gallery>
</gallery>


[[Category:Calibration fixtures]]
[[Category:Calibration fixtures]]
[[Category:Pulse generators]]
[[Category:Pulse generators]]

Revision as of 10:33, 5 July 2016

The Tektronix 067-0502-01Amplitude Calibrator and Comparator is an instrument that can be used to produce a reference rectangle voltage or current waveform and/or to compare an external unknown input with an internal or external reference.

The comparison is performed using an Airpax A175 chopper to switch between the two voltages that are being compared. The resulting output is a rectangular waveform with amplitude equal to the difference of two voltages. It can be amplified and viewed on an oscilloscope.

The use of a chopper to make precise DC measurements is a well known and trusted technique, using instruments that are sensitive to AC, but not capable of drift-free DC performance.

The chopping technique can be used for calibration, comparing a device under test with a reference. In this case, the result of chopping is viewed on an oscilloscope oscilloscope, possibly with a preamplifier between the output of the chopper and the input of the oscilloscope.

The operator adjusts the device under test to minimize the amplitude observed on the oscilloscope. The vertical sensitivity, DC accuracy, and DC drift performance of the oscilloscope and preamplifier are not critical if the goal is simply to calibrate the device under test for optimal match with reference. However, if the objective of the calibration is to provide assurance that the error is less than some specific value, then the gain of the preamplifier and oscilloscope matters. Still, the gain of the preamp and oscilloscope only affect the accuracy of the tolerance, which is typically around 10%, (e.g., +/- 0.01% or +/- 0.3%).

See the 067-0502-00 page for a comparison of the -00 and -01 models.

Key Specifications

  • please add

Manuals

Pictures