067-0532-01: Difference between revisions

From TekWiki
Jump to navigation Jump to search
(Initial page layout. More to come.)
No edit summary
Line 1: Line 1:
[[File:067-0532-01 front.JPG|400px|thumb|right]]
[[File:067-0532-01 front.JPG|350px|thumb|right|Tektronix 067-0532-01 Constant Amplitude Signal Generator]]


The Tektronix '''Type 067-0532-01 Calibration Fixture''' is a '''Constant Amplitude Signal Generator''' whose output is a low-distortion sinewave.  It is intended to provide a signal of known frequency and amplitude for measuring oscilloscope bandwidth.  A 3Mhz sinewave is available as a reference amplitude from which a -3dB measurement can be made.  The output connector, amplitude detector, and 50 ohm source resistor are at the end of a 42 inch cable.  The amplitude is regulated at the end of the cable adjacent to the output connector.  Cable loss and standing-wave errors are essentially eliminated.   
The Tektronix '''Type 067-0532-01 Calibration Fixture''' is a '''Constant Amplitude Signal Generator''' whose output is a low-distortion sinewave.  It is intended to provide a signal of known frequency and amplitude for measuring oscilloscope bandwidth.   


A 3 MHz sinewave is available as a reference amplitude from which a -3 dB measurement can be made.  The output connector, amplitude detector, and 50 Ω source resistor are at the end of a 42 inch cable. The amplitude is regulated at the end of the cable adjacent to the [[GR-874 connector|GR-874 output connector]], thus essentially eliminating cable loss and standing-wave errors.


{{BeginSpecs}}
{{BeginSpecs}}


 
{{SpecGroup| Frequency}}
{{Spec | Frequency|}}
{{Spec | Range | 65 MHz to 500 MHz}}
{{Spec | Range | 65Mhz to 500Mhz}}
{{Spec | Accuracy | Within 2% of indicated frequency }}
{{Spec | Accuracy | Within 2% of indicated frequency }}
{{Spec | 3Mhz Frequency Accuracy | Within 5%)}}
{{Spec | 3 MHz Frequency Accuracy | Within 5%}}
 


{{Spec | Amplitude|}}
{{SpecGroup | Amplitude}}
{{Spec | Range | 0.5V P-P to 4V P-P into 50Ω in .5V increments}}
{{Spec | Range | 0.5 V<sub>p-p</sub> to 4 V<sub>p-p</sub> into 50 Ω in 0.5 V increments}}
{{Spec | Variable | Continuously Variable between calibrated steps. Max Output 4.2V}}
{{Spec | Variable | Continuously variable between calibrated steps. Max. output 4.2 V}}
{{Spec | 3Mhz Amplitude Accuracy | Within 2% of indicated amplitude}}
{{Spec | 3 MHz Amplitude Accuracy | Within 2% of indicated amplitude}}


{{Spec | Constant Amplitude Accuracy|}}
{{SpecGroup | Constant Amplitude Accuracy}}
{{Spec | 65Mhz to 300Mhz | Within 2% of indicated amplitude}}
{{Spec | 65 MHz to 300 MHz | Within 2% of indicated amplitude}}
{{Spec | 300Mhz to 500Mhz| Within 5% of indicated amplitude}}
{{Spec | 300 MHz to 500 MHz | Within 5% of indicated amplitude}}
{{Spec | Output Source Impedance | 50&Omega; within 1%}}
{{Spec | Output Source Impedance | 50 Ω within 1%}}
{{EndSpecs}}
{{EndSpecs}}


Line 27: Line 26:


* [http://w140.com/tek_067-0532-01.pdf Tektronix 067-0532-01 Manual (PDF)]
* [http://w140.com/tek_067-0532-01.pdf Tektronix 067-0532-01 Manual (PDF)]


==Pictures==
==Pictures==
Line 39: Line 37:
File:067-0532-01 signal gen circuit.JPG  | Signal Generator Circuit
File:067-0532-01 signal gen circuit.JPG  | Signal Generator Circuit
File:067-0532-01 line filter.JPG          | Line Filter Board
File:067-0532-01 line filter.JPG          | Line Filter Board
</gallery>
</gallery>




[[Category:Signal generators]]
[[Category:Signal generators]]

Revision as of 00:08, 25 February 2016

Tektronix 067-0532-01 Constant Amplitude Signal Generator

The Tektronix Type 067-0532-01 Calibration Fixture is a Constant Amplitude Signal Generator whose output is a low-distortion sinewave. It is intended to provide a signal of known frequency and amplitude for measuring oscilloscope bandwidth.

A 3 MHz sinewave is available as a reference amplitude from which a -3 dB measurement can be made. The output connector, amplitude detector, and 50 Ω source resistor are at the end of a 42 inch cable. The amplitude is regulated at the end of the cable adjacent to the GR-874 output connector, thus essentially eliminating cable loss and standing-wave errors.

Key Specifications

     — Frequency
Range 65 MHz to 500 MHz
Accuracy Within 2% of indicated frequency
3 MHz Frequency Accuracy Within 5%
     — Amplitude
Range 0.5 Vp-p to 4 Vp-p into 50 Ω in 0.5 V increments
Variable Continuously variable between calibrated steps. Max. output 4.2 V
3 MHz Amplitude Accuracy Within 2% of indicated amplitude
     — Constant Amplitude Accuracy
65 MHz to 300 MHz Within 2% of indicated amplitude
300 MHz to 500 MHz Within 5% of indicated amplitude
Output Source Impedance 50 Ω within 1%