The '''Tektronix 067-0587-10''' is a Calibration fixture / signal standardizer for [[7000-series scopes]].
{{Plugin Sidebar 
It has the same performance specifications as the [[067-0587-02]] but is modified for
|manufacturer=Tektronix  
compatibility with the [[7612D]].  In the [[067-0587-10]] the signal coming from the
|type=067-0587-10  
PRETRIG OUT generates one trigger for each staircase signal when used withthe TEST switch
|summary=calibration fixture  
in the GAIN position.  The [[067-0587-02]] generates a pretrigger signal on the PRETRIG OUT
|image=Tek 067-0587-10.JPG
connector while in any mode.
|caption=067-0587-10  
 
|series=7000-series scopes
==Manuals==
|introduced=(?)
|discontinued=(?)
|manuals=
* [http://w140.com/tek_067-0587-10_op.pdf 067-0587-10 Operator's Manual]
* [http://w140.com/tek_067-0587-10_op.pdf 067-0587-10 Operator's Manual]
* [http://w140.com/tek_067-0587-10_service.pdf 067-0587-10 Service Manual]
* [http://w140.com/tek_067-0587-10_service.pdf 067-0587-10 Service Manual]
}}
The '''Tektronix 067-0587-10''' is a calibration fixture / signal standardizer for [[7000-series scopes]].
It has the same performance specifications as the [[067-0587-02]] but is modified for compatibility with the [[7612D]]. 
In the [[067-0587-10]], the signal coming from the PRETRIG OUT generates one trigger for each staircase signal when used with the TEST switch in the GAIN position. 
The [[067-0587-02]] generates a pre-trigger signal on the PRETRIG OUT connector while in any mode.
{{BeginSpecs}}
{{SpecGroup | GAIN mode }}
{{Spec | Staircase accuracy | ± 0.3% in ± 3 Div, ± 0.5% in ± 4 Div, Linearity ± 0.2% of 10 Div }}
{{SpecGroup |  STEP RESP mode }}
{{Spec | Amplitude | 2 to 10 Div }}
{{Spec | Position  | Top at least ±5 Div from center of screen }}
{{Spec | Rise time | < 150 ps}}
{{Spec | Repetition rate | 10 Hz to 1 MHz in decade steps, 0.1 %}}
{{Spec | Pretrig Out | 0.5 V into 50 Ω, 55 to 95 ns lead time (internally variable) }}
{{SpecGroup |  FREQ RESP mode }}
{{Spec | Input impedance | 50 Ω }}
{{Spec | Input range    | 0.5 to 1 V<sub>p-p</sub> }}
{{Spec | Flatness | ± 3% from 3 MHz to 1 GHz }}
{{EndSpecs}}


==Pictures==
<gallery>
<gallery>
File:Tek 067-0587-10.JPG
Tek 067-0587-10.JPG
Tek-067-0587-02 left.jpg  | 067-0587-10 left side (cam switch assembly on bottom left)
Tek-067-0587-02 right.jpg  | 067-0587-10 right side − note extra switch and resistor in top middle area of PCB that differentiates it from [[067-0587-02]]
067-0587-10_11k_mod_rear.jpg | 067-0587-10 with modified rear plastic interface to fit [[11000-series scopes]]
</gallery>
</gallery>


[[Category:Image needed]]
{{Custom ICs|067-0587-10}}
 
[[Category:Specifications needed]]


[[Category:7000 series special-function plugins]]


[[Category:Calibration fixtures]]
[[Category:Calibration fixtures]]
[[Category:7000 series test and calibration plugins]]

Revision as of 10:21, 19 August 2021

Tektronix 067-0587-10
calibration fixture
067-0587-10

Compatible with 7000-series scopes

Produced from (?) to (?)

Manuals
(All manuals in PDF format unless noted otherwise)
Manuals – Specifications – Links – Pictures

The Tektronix 067-0587-10 is a calibration fixture / signal standardizer for 7000-series scopes. It has the same performance specifications as the 067-0587-02 but is modified for compatibility with the 7612D.

In the 067-0587-10, the signal coming from the PRETRIG OUT generates one trigger for each staircase signal when used with the TEST switch in the GAIN position. The 067-0587-02 generates a pre-trigger signal on the PRETRIG OUT connector while in any mode.

Key Specifications

     — GAIN mode
Staircase accuracy ± 0.3% in ± 3 Div, ± 0.5% in ± 4 Div, Linearity ± 0.2% of 10 Div
     — STEP RESP mode
Amplitude 2 to 10 Div
Position Top at least ±5 Div from center of screen
Rise time < 150 ps
Repetition rate 10 Hz to 1 MHz in decade steps, 0.1 %
Pretrig Out 0.5 V into 50 Ω, 55 to 95 ns lead time (internally variable)
     — FREQ RESP mode
Input impedance 50 Ω
Input range 0.5 to 1 Vp-p
Flatness ± 3% from 3 MHz to 1 GHz

Pictures


Custom ICs used in the 067-0587-10

Page Model Part nos Description Designers Used in
155-0160-00 M136 155-0160-00 1.5 GHz trigger amplifier and source select Art Metz 7B10 7B15 067-0587-02 067-0587-10
155-0175-00 H476 155-0175-00 155-0175-05 broadband amplifier John Addis Wink Gross Carl Battjes 7904A 7912HB 7934 7104 R7103 7A29 7A29P 7F10 067-0587-02 067-0587-10 11A71 SCD1000 EG&G N-AM-173A
155-0182-00 H672 155-0182-00 Schottky diode shaper 067-0587-02 067-0587-10
155-0183-00 H672 155-0183-00 Schottky diode detector Art Metz 067-0587-02 067-0587-10