Difference between revisions of "067-0680-00"

From TekWiki
Jump to navigation Jump to search
(New page: * [http://w140.com/tek_067-0680-00.pdf Tektronix 067-0680-00 Manual (PDF)])
 
 
(10 intermediate revisions by 2 users not shown)
Line 1: Line 1:
* [http://w140.com/tek_067-0680-00.pdf Tektronix 067-0680-00 Manual (PDF)]
+
{{Plugin Sidebar
 +
|manufacturer=Tektronix
 +
|series=5000-series scopes
 +
|type=067-0608-00
 +
|summary=5000 series mainframe calibrator
 +
|image=067-0680-00-front.jpg
 +
|caption=Tektronix 067-0608-00 cal fixture
 +
|introduced=(?)
 +
|discontinued=(?)
 +
|designers=
 +
|manuals=
 +
* [[Media:062-1587-00.pdf|Tektronix 067-0680-00 Manual, First Revision (PDF, OCR)]]
 +
* [http://w140.com/tek_067-0680-00.pdf Tektronix 067-0680-00 Manual, Second Revision (PDF)]
 +
}}
 +
The '''Tektronix 067-0680-00''' is a plug-in used to calibrate a 5400-series mainframe's
 +
horizontal and vertical deflection factors and step response, and help align CRT geometry.
 +
 
 +
It provides a calibrated stair-step signal for deflection factor and geometry adjustment, a fast-risetime step function for checking and trimming step response, a leveling circuit for an external sinewave test signal, and a common-mode input test for both the vertical and trigger systems.
 +
 
 +
It is similar to the [[067-0587-01|067-0587-xx]] for [[7000 series scopes]].
 +
 
 +
{{MissingSpecs}}
 +
 
 +
==Pictures==
 +
<gallery>
 +
067-0680-00-front.jpg
 +
Tek 067-0680-00.JPG
 +
Tek 067-0680-00 internal.jpg
 +
Tek 067-0680-00 internal 2.jpg
 +
Tek 067-0680-l.jpg
 +
Tek 067-0680-r.jpg
 +
</gallery>
 +
 
 +
 
 +
[[Category:Calibration fixtures]]
 +
[[Category:5000 series plugins]]

Latest revision as of 10:47, 15 August 2021

Tektronix 067-0608-00
5000 series mainframe calibrator
Tektronix 067-0608-00 cal fixture

Compatible with 5000-series scopes

Produced from (?) to (?)

Manuals


Manuals – Specifications – Links – Pictures

The Tektronix 067-0680-00 is a plug-in used to calibrate a 5400-series mainframe's horizontal and vertical deflection factors and step response, and help align CRT geometry.

It provides a calibrated stair-step signal for deflection factor and geometry adjustment, a fast-risetime step function for checking and trimming step response, a leveling circuit for an external sinewave test signal, and a common-mode input test for both the vertical and trigger systems.

It is similar to the 067-0587-xx for 7000 series scopes.

Specifications

  • please add

Pictures