Each plug-in bay in the 129 has an output circuit card.  The deflection signal output on pins 17 and 21 of the plug-in
Each plug-in bay in the 129 has an output circuit card.  The deflection signal output on pins 17 and 21 of the plug-in
drive the output circuit card.  There are two varieties of output circuit card: active (cathode-follower) and passive.
drive the output circuit card.  There are two varieties of output circuit card: active (cathode-follower) and passive.
To use sampling plug-ins in the 129, active output circuit cards are required.
To use [[sampling oscilloscope|sampling]] plug-ins in the 129, active output circuit cards are required.
 
The power supply of the 129 is linear and consists of a power transformer followed by uses silicon rectifiers, electrolytic
capacitors, and then regulators.  Not all of the supply voltages are regulated.  A [[ZZ1000]] tube is used as the voltage reference.
The regulators (feedback amplifiers and output tubes) are all tube, except for the high-current -12.2V regulated supply.  This one
uses bipolar transistors for the feedback amplifier and output device.  The -12.2V supply is independently fused.  The other supplies are
not independently fused.  The 129 has a 6.25A fuse on the primary of the mains transformer.