132: Difference between revisions

No change in size ,  13 June 2017
m
93 ohm termination for max bandwidth, not 50 ohm
No edit summary
m (93 ohm termination for max bandwidth, not 50 ohm)
Line 27: Line 27:
The gain and bandwidth of the entire system (plug-in + 132 + load) depend on the load impedance.
The gain and bandwidth of the entire system (plug-in + 132 + load) depend on the load impedance.
For exact gain, the 132 needs to be terminated with an exact impedance.
For exact gain, the 132 needs to be terminated with an exact impedance.
A load impedance of 50 Ω maximizes bandwidth and further reductions of load impedance
A load impedance of 93 Ω maximizes bandwidth and further reductions of load impedance
only reduce the available output swing.  A load impedance of 50 kΩ maximizes gain and further
only reduce the available output swing.  A load impedance of 50 kΩ maximizes gain and further
increases in load impedance have little effect on system performance.
increases in load impedance have little effect on system performance.
118

edits