1M1: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
No edit summary
 
(11 intermediate revisions by 4 users not shown)
Line 1: Line 1:
{{Plugin Sidebar 2|
{{Plugin Sidebar
title=Tektronix 1M1 |
|manufacturer=Tektronix
summary=Calibration plug-in |
|series=500-series scopes
image=Tek 1m1 front.jpg |
|type=1M1  
caption=Tek 1M1 |
|summary=Calibration plug-in  
series=[[500-series scopes]] |
|image=Tek 1m1 front.jpeg
introduced=1964 |
|caption=Tektronix 1M1  
discontinued=(?) |
|introduced=1964  
manuals=
|discontinued=(?)  
* [[Media:070-0407-01.pdf|Tektronix 067-0521-00 Manual (PDF)]]
|designers=
* [[Media:070-0407-02.pdf|Tektronix 067-0521-01 Manual (PDF)]]
|manuals=
* [http://w140.com/tek_tu-7_rough.pdf Tektronix TU-7 Manual (rough scan, OCR, PDF)]
* [[Media:070-407.pdf | Tektronix TU-7 Manual]] (070-407; rough scan, OCR)
* [http://bama.edebris.com/manuals/tek/tu7 1M1 / TU-7 / 067-0521-00 Manual on BAMA (offline?)]
* [[Media:070-0407-01.pdf | Tektronix 067-0521-00 Manual]] (070-0407-01; OCR)
* [[Media:067-0521-00.pdf|Tektronix 067-0521-00 (PDF, OCR, bad-OCR)]]
* [[Media:070-0407-02.pdf | Tektronix 067-0521-01 Manual]] (070-0407-02; OCR)
* [[Media:067-0521-01.pdf|Tektronix 067-0521-01 (PDF, OCR, bad-OCR)]]
* [[Media:Tek tu-7 irb.pdf | Tektronix TU-7 Instrument Reference Book]] (OCR)
* [[Media:bama_manuals_tek_1m1_tu-7.pdf|1M1 / TU-7 / 067-0521-00 Manual on BAMA (PDF, OCR, bad-OCR)]]
* [[Media:Tek 067-0521-00 fcp july 1969.pdf | Tektronix 067-0521-00 Factory Calibration Procedure, July 1969‎]]
* [[Media:Tek tu-7 irb.pdf|Tektronix TU-7 Instrument Reference Book (PDF, OCR)]]
* [[Media:Tek 067-0521-00 fcp july 1969.pdf|Tektronix 067-0521-00 Factory Calibration Procedure, July 1969‎]]
 
[[Category:500 series plugins]]
[[Category:Calibration fixtures]]
}}
}}
The '''Tektronix [[TU-7]]/1M1/[[067-0521-00]]''' is a [[Letter-series_and_1-series_plug-ins|letter series plug-in]]  
The '''Tektronix TU-7/1M1/067-0521-00''' is a [[Letter-series_and_1-series_plug-ins|letter series plug-in]] used for calibrating [[500-series scopes]].   
used for calibrating [[500-series scopes]].   


It is a multifunction replacement for the [[P|Type P Pulser]], the [[TU-2|TU-2 Test Load]],
It is a multifunction replacement for the [[P|Type P Pulser]], the [[TU-2|TU-2 Test Load]], and the [[EP-53|EP-53 Gain Set Adaptor]].   
and the [[EP-53|EP-53 Gain Set Adaptor]].   


It is used for calibrating the mainframe's step response and gain,
It is used for calibrating the mainframe's step response and gain, checking dual-trace operation, common mode rejection, and power supply regulation.   
checking dual-trace operation, common mode rejection, and power supply regulation.   


(500-series mainframes are designed to have
(500-series mainframes are designed to have 10 div/Volt response to differential signals from the plug-in, and zero response to common-mode signals.)
10 div/Volt response to differential signals from the plug-in,
and zero response to common-mode signals.)


It contains a transistor multivibrator whose output is sharpened
It contains a transistor multivibrator whose output is sharpened through Tektronix-made Gallium-Arsenide diodes (later production used silicon), a dual-trace circuit using [[12AT7]] and [[6AL5]] tubes, and various load resistors. It does not have the Type P's short operating life because it does not use a [[mercury switch]].
through Tek-made Gallium-Arsenide diodes (later production used silicon),  
a dual-trace circuit using [[12AT7]] and [[6AL5]] tubes, and various load resistors.
It does not have the Type P's short operating life because it does not use a [[mercury switch]].


This instrument went through several names.
This instrument went through several names. At its [[introduced in 1964|1964]] introduction, it was the '''TU-7'''.   
At its [[introduced in 1964|1964]] introduction, it was the '''TU-7'''.   
Some early Tektronix internal instruments for design, manufacturing, and calibration had TU (Test Unit) nomenclature.   
Some early Tek-internal instruments for design,
(Other examples include the [[TU-75B]] Variac, and the [[TU-50]] sine/square/pulse generator.)   
manufacturing, and calibration had TU (Test Unit) nomenclature.   
(Other examples include the [[TU-75B]] Variac, the TU-?? dim-bulb fixture,
and the [[TU-50]] sine/square/pulse generator.)   


In 1965, it was renamed '''Type 1M1''' to fit into the letter-series nomenclature like its predecessor.   
In 1965, it was renamed '''Type 1M1''' to fit into the letter-series nomenclature.   
Later still, the 067- calibration fixture naming system took hold and it was rechristened '''067-0521-00'''.   
Later still, the 067- calibration fixture naming system took hold and it was rechristened '''067-0521-00'''.   


The instrument was also revised once - more pulse frequencies - and the name upgraded to '''067-0521-01'''.  
The instrument was also revised once - more pulse frequencies - and the name upgraded to '''067-0521-01'''.  


It does not appear - under any name - in any Tek catalog, but the 1964 catalog <u>does</u> list a cousin:  
It does not appear - under any name - in any Tektronix catalog, but the 1964 catalog <u>does</u> list a cousin:  
Type [[10/11M1]], for the [[647|Type 647]] scope.
Type [[10/11M1]], for the [[647|Type 647]] scope.


Line 60: Line 44:


<gallery>
<gallery>
067-0521-00 1.JPG
067-0521-00 1.JPG | 067-0521-00
Tek 1m1 front.jpg
Tek 1m1 front.jpg | 1M1 Front
Tek 1m1 right.jpg
Tek 1m1 right.jpg | 1M1 RHS
Tek 1m1 left.jpg
Tek 1m1 left.jpg | 1M1 LHS
Tek tu-7 c1.jpg|TU-7 variant with five repetition rates
Tek tu-7 c1.jpg | TU-7 variant with five repetition rates
Tek tu-7 c2.jpg|TU-7 variant with five repetition rates
Tek tu-7 c2.jpg | TU-7 variant with five repetition rates
Tek tu-7 c3.jpg|TU-7 variant with five repetition rates
Tek tu-7 c3.jpg | TU-7 variant with five repetition rates
Tek tu-7 c4.jpg|TU-7 variant with five repetition rates
Tek tu-7 c4.jpg | TU-7 variant with five repetition rates
Tek tu-7 c5.jpg|TU-7 variant with five repetition rates
Tek tu-7 c5.jpg | TU-7 variant with five repetition rates
Tek_067-0521-01_Front.jpeg | 067-0521-01 Front
Tek_067-0521-01_LHS.jpeg | 067-0521-01 LHS
Tek_067-0521-01_RHS.jpeg | 067-0521-01 RHS
Tek_067-0521-01_Top.jpeg | 067-0521-01 Top
Tek_067-0521-01_Bottom.jpeg | 067-0521-01 Bottom
Tek_067-0521-01_Diodes.jpeg | 067-0521-01 Schottky Diodes (pulse generator)
Tek_067-0521-01_Pulse.jpeg | 067-0521-01 Vertical amp step response test on a 547
Tek_067-0521-01_Chopped.jpeg | 067-0521-01 Chopped trace test signal
</gallery>
</gallery>
==Components==
{{Parts|1M1}}


[[Category:500 series plugins]]
[[Category:500 series plugins]]
[[Category:Calibration fixtures]]
[[Category:Calibration fixtures]]

Latest revision as of 08:23, 6 December 2023

Tektronix 1M1
Calibration plug-in
Tektronix 1M1

Compatible with 500-series scopes

Produced from 1964 to (?)

Manuals
Manuals – Specifications – Links – Pictures

The Tektronix TU-7/1M1/067-0521-00 is a letter series plug-in used for calibrating 500-series scopes.

It is a multifunction replacement for the Type P Pulser, the TU-2 Test Load, and the EP-53 Gain Set Adaptor.

It is used for calibrating the mainframe's step response and gain, checking dual-trace operation, common mode rejection, and power supply regulation.

(500-series mainframes are designed to have 10 div/Volt response to differential signals from the plug-in, and zero response to common-mode signals.)

It contains a transistor multivibrator whose output is sharpened through Tektronix-made Gallium-Arsenide diodes (later production used silicon), a dual-trace circuit using 12AT7 and 6AL5 tubes, and various load resistors. It does not have the Type P's short operating life because it does not use a mercury switch.

This instrument went through several names. At its 1964 introduction, it was the TU-7. Some early Tektronix internal instruments for design, manufacturing, and calibration had TU (Test Unit) nomenclature. (Other examples include the TU-75B Variac, and the TU-50 sine/square/pulse generator.)

In 1965, it was renamed Type 1M1 to fit into the letter-series nomenclature. Later still, the 067- calibration fixture naming system took hold and it was rechristened 067-0521-00.

The instrument was also revised once - more pulse frequencies - and the name upgraded to 067-0521-01.

It does not appear - under any name - in any Tektronix catalog, but the 1964 catalog does list a cousin: Type 10/11M1, for the Type 647 scope.

Links

Pictures

Components

Some Parts Used in the 1M1

Part Part Number(s) Class Description Used in
12AT7 154-0039-00 Vacuum Tube (Dual Triode) dual high-gain triode 161 180 310 310A 315 316 360 502 502A 511A 512 513 513D 514 514AD 514D 516 524 529 RM529 544 546 547 556 565 570 3A2 75 3A75 1M1 A B C G H K L ML M N K R S Z
6AL5 154-016 154-0016-00 154-0038-00 Vacuum Tube (Dual Diode) high-perveance dual diode 163 181 190 1M1 310 310A 315 316 317 3B1 3B1S 3B2 3B3 3B5 502 502A 503 511 511A 512 516 517 517A 524 526 535 535A 545 545A 549 551 565 570 581 581A 585 585A C T Telequipment D56 Telequipment S52