1M1: Difference between revisions

70 bytes added ,  15 November 2023
m
add a few captions, minor edits
No edit summary
m (add a few captions, minor edits)
Line 5: Line 5:
|summary=Calibration plug-in  
|summary=Calibration plug-in  
|image=Tek 1m1 front.jpeg  
|image=Tek 1m1 front.jpeg  
|caption=Tek 1M1  
|caption=Tektronix 1M1  
|introduced=1964  
|introduced=1964  
|discontinued=(?)  
|discontinued=(?)  
|designers=
|designers=
|manuals=
|manuals=
* [[Media:070-407.pdf|Tektronix TU-7 Manual]] (070-407; rough scan, OCR)
* [[Media:070-407.pdf | Tektronix TU-7 Manual]] (070-407; rough scan, OCR)
* [[Media:070-0407-01.pdf|Tektronix 067-0521-00 Manual]] (070-0407-01; OCR)
* [[Media:070-0407-01.pdf | Tektronix 067-0521-00 Manual]] (070-0407-01; OCR)
* [[Media:070-0407-02.pdf|Tektronix 067-0521-01 Manual]] (070-0407-02; OCR)
* [[Media:070-0407-02.pdf | Tektronix 067-0521-01 Manual]] (070-0407-02; OCR)
* [[Media:Tek tu-7 irb.pdf|Tektronix TU-7 Instrument Reference Book]] (OCR)
* [[Media:Tek tu-7 irb.pdf | Tektronix TU-7 Instrument Reference Book]] (OCR)
* [[Media:Tek 067-0521-00 fcp july 1969.pdf|Tektronix 067-0521-00 Factory Calibration Procedure, July 1969‎]]
* [[Media:Tek 067-0521-00 fcp july 1969.pdf | Tektronix 067-0521-00 Factory Calibration Procedure, July 1969‎]]
}}
}}
The '''Tektronix [[TU-7]]/1M1/[[067-0521-00]]''' is a [[Letter-series_and_1-series_plug-ins|letter series plug-in]] used for calibrating [[500-series scopes]].   
The '''Tektronix [[TU-7]]/1M1/[[067-0521-00]]''' is a [[Letter-series_and_1-series_plug-ins|letter series plug-in]] used for calibrating [[500-series scopes]].   
Line 24: Line 24:
(500-series mainframes are designed to have 10 div/Volt response to differential signals from the plug-in, and zero response to common-mode signals.)
(500-series mainframes are designed to have 10 div/Volt response to differential signals from the plug-in, and zero response to common-mode signals.)


It contains a transistor multivibrator whose output is sharpened through Tek-made Gallium-Arsenide diodes (later production used silicon), a dual-trace circuit using [[12AT7]] and [[6AL5]] tubes, and various load resistors.  It does not have the Type P's short operating life because it does not use a [[mercury switch]].
It contains a transistor multivibrator whose output is sharpened through Tektronix-made Gallium-Arsenide diodes (later production used silicon), a dual-trace circuit using [[12AT7]] and [[6AL5]] tubes, and various load resistors.  It does not have the Type P's short operating life because it does not use a [[mercury switch]].


This instrument went through several names. At its [[introduced in 1964|1964]] introduction, it was the '''TU-7'''.   
This instrument went through several names. At its [[introduced in 1964|1964]] introduction, it was the '''TU-7'''.   
Some early Tek-internal instruments for design, manufacturing, and calibration had TU (Test Unit) nomenclature.   
Some early Tektronix internal instruments for design, manufacturing, and calibration had TU (Test Unit) nomenclature.   
(Other examples include the [[TU-75B]] Variac, and the [[TU-50]] sine/square/pulse generator.)   
(Other examples include the [[TU-75B]] Variac, and the [[TU-50]] sine/square/pulse generator.)   


In 1965, it was renamed '''Type 1M1''' to fit into the letter-series nomenclature like its predecessor.   
In 1965, it was renamed '''Type 1M1''' to fit into the letter-series nomenclature.   
Later still, the 067- calibration fixture naming system took hold and it was rechristened '''067-0521-00'''.   
Later still, the 067- calibration fixture naming system took hold and it was rechristened '''067-0521-00'''.   


The instrument was also revised once - more pulse frequencies - and the name upgraded to '''067-0521-01'''.  
The instrument was also revised once - more pulse frequencies - and the name upgraded to '''067-0521-01'''.  


It does not appear - under any name - in any Tek catalog, but the 1964 catalog <u>does</u> list a cousin:  
It does not appear - under any name - in any Tektronix catalog, but the 1964 catalog <u>does</u> list a cousin:  
Type [[10/11M1]], for the [[647|Type 647]] scope.
Type [[10/11M1]], for the [[647|Type 647]] scope.


Line 44: Line 44:


<gallery>
<gallery>
067-0521-00 1.JPG
067-0521-00 1.JPG | 067-0521-00
Tek 1m1 front.jpg
Tek 1m1 front.jpg | 1M1 Front
Tek 1m1 right.jpg
Tek 1m1 right.jpg | 1M1 RHS
Tek 1m1 left.jpg
Tek 1m1 left.jpg | 1M1 LHS
Tek tu-7 c1.jpg|TU-7 variant with five repetition rates
Tek tu-7 c1.jpg | TU-7 variant with five repetition rates
Tek tu-7 c2.jpg|TU-7 variant with five repetition rates
Tek tu-7 c2.jpg | TU-7 variant with five repetition rates
Tek tu-7 c3.jpg|TU-7 variant with five repetition rates
Tek tu-7 c3.jpg | TU-7 variant with five repetition rates
Tek tu-7 c4.jpg|TU-7 variant with five repetition rates
Tek tu-7 c4.jpg | TU-7 variant with five repetition rates
Tek tu-7 c5.jpg|TU-7 variant with five repetition rates
Tek tu-7 c5.jpg | TU-7 variant with five repetition rates
Tek_067-0521-01_Front.jpeg | 067-0521-01 Front
Tek_067-0521-01_Front.jpeg | 067-0521-01 Front
Tek_067-0521-01_LHS.jpeg | 067-0521-01 LHS
Tek_067-0521-01_LHS.jpeg | 067-0521-01 LHS
1,325