1 row is stored for this pageManufacturer | Tektronix |
Model | 2215 |
Class | Oscilloscope |
Description | 60 MHz dual trace scope |
Series | 2200-series scopes |
Introduced | 1982 |
Discontinued | (?) |
"Specifications" values
15 rows are stored for this pageParameter | Deflection |
Value | 2 mV/div to 10 V/div, 1-2-5 |
Parameter | Rise time |
Value | < 5.8 ns (calculated) |
Parameter | Bandwidth |
Value | DC to >60 MHz, 20 mV/Div to 10 V/Div, 0 °C to +40 °C; >50 MHz in 2 mV/Div to 10 mV/Div ranges or from +40 °C to +50 °C |
Parameter | Input impedance |
Value | 1 MΩ ±2% // 30 ±3 pF |
Parameter | Maximum Safe Input Voltage |
Value | 400 V (DC + peak AC) or 800 Vp-p AC to 1 kHz or less |
Parameter | CMRR |
Value | At least 10:1 at 10 MHz |
Parameter | Timebase |
Value | 50 ns/Div to 500 ms/Div, 1-2-5, ×10 magnifier, i.e. down to 5 ns/Div |
Parameter | Trigger sensitivity |
Value | 0.4 Div internal / 50 mV external up to 2 MHz; 1.5 Div internal / 250 mV external up to 60 MHz; AC coupled ≥10 Hz |
Parameter | External trigger input |
Value | max. 400 V (DC+peak AC) or 800 Vp-p AC to 1 kHz or less; impedance 1 MΩ ±2% // 30 ±3 pF |
Parameter | Trigger modes |
Value | Auto, Norm, TV Field |
Parameter | Z axis |
Value | input (intensity); DC to 5 MHz |
Parameter | CRT |
Value | display area : 80 × 100 mm² |
Parameter | Weight |
Value | 6.1 kg; 7.6 kg with front panel cover, accessories and pouch |
Parameter | Dimensions |
Value | With feet and handle: 137 x 361 x 511 mm³ |
Parameter | Features |