2236: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
No edit summary
(2 intermediate revisions by 2 users not shown)
Line 12: Line 12:
* [[Media:070-4204-00_Nov_1986.pdf|Tektronix 2236 Manual (Nov 1986) (PDF, OCR, bad-OCR)]]
* [[Media:070-4204-00_Nov_1986.pdf|Tektronix 2236 Manual (Nov 1986) (PDF, OCR, bad-OCR)]]
* [[Media:070-7685-00.pdf|Tektronix 2236A Instruction manual (PDF)]]
* [[Media:070-7685-00.pdf|Tektronix 2236A Instruction manual (PDF)]]
* [http://www.hakanh.com/dl/docs/hardtofind/SUP3010.pdf Tektronix Service Update Plan 3010, CRT filament voltage reduction] (1983)
* [[Media:070-4205-00.pdf|Tektronix 2236 Operators Manual (PDF, OCR)]]
}}
}}
The '''Tektronix 2236''' is a 100 MHz portable scope with a dual time base
The '''Tektronix 2236''' is a 100 MHz portable scope with a dual time base
Line 17: Line 19:
Apart from the counter, it is the same as the [[2235]].
Apart from the counter, it is the same as the [[2235]].


IN addition to signal frequency and period, the counter can measure delay time and delta time from the delayed timebase.
In addition to signal frequency and period, the counter can measure delay time and delta time from the delayed timebase.
{{BeginSpecs}}
{{BeginSpecs}}
{{Spec | Bandwidth | 90 MHz at 2 mV/Div, 100 MHz at 5 mV/Div and above; switchable 20 MHz limit }}
{{Spec | Bandwidth | 90 MHz at 2 mV/Div, 100 MHz at 5 mV/Div and above; switchable 20 MHz limit }}
{{Spec | Rise time | 3.9 ns at 2 mV/Div, 3.5 ns at 5 mV/Div and above  }}
{{Spec | Rise time | 3.9 ns at 2 mV/Div, 3.5 ns at 5 mV/Div and above  }}
{{Spec | Deflection | 2 mV/Div to 5 V/Div, 1−2−5, ±2%, and variable 2.5:1  }}
{{Spec | Deflection | 2 mV/Div to 5 V/Div, 1−2−5, ±2%, and variable 2.5:1  }}
{{Spec | Time base | 50 ns/Div to 500 ms/Div (B timebase to 50 ms/Div), 1−2−5,  ×10 magnifier for fastest deflection of 5 ns/Div  }}
{{Spec | Time base | 50 ns/Div to 500 ms/Div (B timebase to 50 ms/Div), 1−2−5, ×10 magnifier for fastest deflection of 5 ns/Div  }}
{{Spec | Frequency counter | 7 digit resolution; frequency 100 Hz to 100 MHz in decade ranges, period 100 μs to 1 s in decade ranges, plus 5 s range; time base accuracy 1×10<sup>-5</sup> (Opt.14: 5×10<sup>-7</sup>), sensitivity same as trigger specs }}
{{Spec | Frequency counter | 7 digit resolution; frequency 100 Hz to 100 MHz in decade ranges, period 100 μs to 1 s in decade ranges, plus 5 s range; time base accuracy 1×10<sup>-5</sup> (Opt.14: 5×10<sup>-7</sup>), sensitivity same as trigger specs }}
{{Spec | Multimeter | 3¾ digit resolution, ≥2.5 measurements per second, 10 MΩ input resistance, input isolated from scope ground; DC volts 0.5 V to 500 V in decade ranges; AC volts RMS 0.5 V to 350 V in decade ranges; resistance 50 Ω to 50 MΩ in decade ranges, plus 200 MΩ and 2 GΩ ranges; temperature -62 °C to +230 °C (with [[P6602]] probe) }}
{{Spec | Multimeter | 3¾ digit resolution, ≥2.5 measurements per second, 10 MΩ input resistance, input isolated from scope ground; DC volts 0.5 V to 500 V in decade ranges; AC volts RMS 0.5 V to 350 V in decade ranges; resistance 50 Ω to 50 MΩ in decade ranges, plus 200 MΩ and 2 GΩ ranges; temperature -62 °C to +230 °C (with [[P6602]] probe) }}

Revision as of 09:09, 1 May 2021

Manuals – Specifications – Links – Pictures

The Tektronix 2236 is a 100 MHz portable scope with a dual time base and a built-in DMM/counter with a dedicated 9-digit VF display. Apart from the counter, it is the same as the 2235.

In addition to signal frequency and period, the counter can measure delay time and delta time from the delayed timebase.

Key Specifications

Bandwidth 90 MHz at 2 mV/Div, 100 MHz at 5 mV/Div and above; switchable 20 MHz limit
Rise time 3.9 ns at 2 mV/Div, 3.5 ns at 5 mV/Div and above
Deflection 2 mV/Div to 5 V/Div, 1−2−5, ±2%, and variable 2.5:1
Time base 50 ns/Div to 500 ms/Div (B timebase to 50 ms/Div), 1−2−5, ×10 magnifier for fastest deflection of 5 ns/Div
Frequency counter 7 digit resolution; frequency 100 Hz to 100 MHz in decade ranges, period 100 μs to 1 s in decade ranges, plus 5 s range; time base accuracy 1×10-5 (Opt.14: 5×10-7), sensitivity same as trigger specs
Multimeter 3¾ digit resolution, ≥2.5 measurements per second, 10 MΩ input resistance, input isolated from scope ground; DC volts 0.5 V to 500 V in decade ranges; AC volts RMS 0.5 V to 350 V in decade ranges; resistance 50 Ω to 50 MΩ in decade ranges, plus 200 MΩ and 2 GΩ ranges; temperature -62 °C to +230 °C (with P6602 probe)
Input impedance 1 MΩ // 20 pF
Trigger sensitivity 0.3 Div or 35 mV up to 10 MHz, 1 Div or 120 mV up to 60 MHz, 1.5 Div or 200 mV up to 100 MHz
CRT 80×100 mm² display area, P31 phosphor, 14 kV acceleration voltage
Power 90−250 VAC, 48 to 440 Hz, 40 W
Size 137 mm × 328 mm × 440 mm (5.4" × 12.9" × 17.3")
Weight 5.2 kg (11.5 lb) without accessories
Features
  • DMM and counter
  • Delayed timebase
  • X−Y mode
  • Z input

Prices

  • 1984: $2,650 (2017 value: $6,240)

Links

Pictures