{{Oscilloscope Sidebar|
{{Oscilloscope Sidebar  
title=Tektronix 2335 |
|manufacturer=Tektronix
image=Tek 2335 front.jpg |
|series=2000-series scopes
caption=Tektronix 2335  |
|model=2335  
introduced=1982 |
|image=Tek 2335 front.jpg  
discontinued=(?) |
|caption=Tektronix 2335   
summary=Ruggedized 100 MHz dual trace scope  |
|introduced=1982  
manuals=
|discontinued=1991
*[http://exodus.poly.edu/~kurt/manuals/manuals/Tektronix/TEK%202335%20Instruction.pdf Tektronix 2335 Instruction Manual (PDF)]
|designers=
*''[[list of manuals that are needed|service manual needed]]''
|summary=Ruggedized 100 MHz dual-trace scope   
* [http://w140.com/Tektronix-2300-Series_Brochure.pdf Tektronix 2300 Series Brochure (PDF)]
|manuals=
* [[Media:070-4115-00.pdf|Tektronix 2335 Operator Manual]] (PDF, OCR, bad-OCR)
* [[Media:070-4116-00.pdf|Tektronix 2335 Service Manual]]
* [[Media:Tektronix-2300-Series_Brochure.pdf| Tektronix 2300 Series Brochure ]] (PDF)
* [[Media:2300_Series_Brochure.pdf| Tektronix 2300 Series Brochure ]] (PDF, OCR)
}}
The '''Tektronix 2335''' is a ruggedized portable dual-channel, 100 MHz analog scope.  An External trigger input on front and External Z-Axis connector at the rear round out its connectivity.


* [[Media:070-4115-00.pdf|Tektronix 2335 Instruction Manual (PDF, OCR)]]
Vertical controls were by way of calibrated deflection factors on CH 1 or CH 2 inputs through AC, DC, or GND coupling. The vertical mode selections are CH 1, BOTH, CH 2, ADD, ALT, CHOP (500 kHz), TRIG VIEW, or BW LIMIT (20 MHz).  Horizontal deflection is controlled by either the calibrated A or B Sweep Generators, or Alternate between the two of the A, and B Delayed Sweep.


* [[Media:2300_Series_Brochure.pdf|Tektronix 2300 Series Brochure (PDF, OCR)]]
Trigger modes may be one of four modes: Single Sweep Reset, P-P Auto-TV Line, Normal, and TV Field.  Trigger sources can be Internal, Line, or External, and can be controlled by amplitude level and slope type. The Internal signal source(s) is(are) from signals applied to channels 1 or 2, or based on what Vertical Mode selected.
}}


The '''Tektronix 2335''' is a ruggedized portable dual channel oscilloscope with 100 MHz bandwidth.
{{BeginSpecs}}
A 150 MHz modification was available.
{{Spec | Bandwidth      | 100 MHz (≥90 MHz at 2 mV/Div) }}
 
{{Spec | Deflection      | CH1, CH2: 5 mV/Div to 5 V/Div, 1–2–5; all ±2%; Variable control can increase sensitivity to at least 2 mV/Div }}
{{MissingSpecs}}
{{Spec | Input Impedance | 1 MΩ ±2% // 20±2 pF }}
{{Spec | Maximum Input  | 400 V (DC + peak AC) or 500 V (p-p ac at ≤ 1 kHz) }}
{{Spec | Sweep          | A Time Base 0.5 s/div to 50 ns/div; B Time Base 50 ms/div to 50 ns/div; A and B ×10 magnifier extends max sweep to 5 ns/div }}
{{Spec | Trigger Source  | INT (CH1, CH2), LINE, EXT (AC, DC, DC ÷ 10) }}
{{Spec | Probes          | Two P6108A 100 MHz ×10 probes, BNC connector with a readout pin }}
{{Spec | Power          | 90 − 250 VAC, 48 − 440 Hz, 40 W max }}
{{EndSpecs}}


==Links==
==Links==
* [[Media:Tekscope 1981 V13 N1.pdf  | TekScope Vol. 13 No. 1, Mar 1981]] p.10+: Three New Portable Oscilloscopes Designed for Field Service Use
* [[Media:Tekscope 1981 V13 N2.pdf  | TekScope Vol. 13 No. 2, June 1981]] p.10+: Three New Portable Oscilloscopes Designed for Field Service Use


==Pictures==
==Pictures==
Line 32: Line 43:
</gallery>
</gallery>


[[Category:2300 series scopes]]
[[Category:Manual needed]]
[[Category:Manual needed]]
[[Category:2300 series scopes]]

Revision as of 14:23, 28 January 2022

Tektronix 2335
Ruggedized 100 MHz dual-trace scope
Tektronix 2335

Produced from 1982 to 1991

Manuals
(All manuals in PDF format unless noted otherwise)
Manuals – Specifications – Links – Pictures

The Tektronix 2335 is a ruggedized portable dual-channel, 100 MHz analog scope. An External trigger input on front and External Z-Axis connector at the rear round out its connectivity.

Vertical controls were by way of calibrated deflection factors on CH 1 or CH 2 inputs through AC, DC, or GND coupling. The vertical mode selections are CH 1, BOTH, CH 2, ADD, ALT, CHOP (500 kHz), TRIG VIEW, or BW LIMIT (20 MHz). Horizontal deflection is controlled by either the calibrated A or B Sweep Generators, or Alternate between the two of the A, and B Delayed Sweep.

Trigger modes may be one of four modes: Single Sweep Reset, P-P Auto-TV Line, Normal, and TV Field. Trigger sources can be Internal, Line, or External, and can be controlled by amplitude level and slope type. The Internal signal source(s) is(are) from signals applied to channels 1 or 2, or based on what Vertical Mode selected.

Key Specifications

Bandwidth 100 MHz (≥90 MHz at 2 mV/Div)
Deflection CH1, CH2: 5 mV/Div to 5 V/Div, 1–2–5; all ±2%; Variable control can increase sensitivity to at least 2 mV/Div
Input Impedance 1 MΩ ±2% // 20±2 pF
Maximum Input 400 V (DC + peak AC) or 500 V (p-p ac at ≤ 1 kHz)
Sweep A Time Base 0.5 s/div to 50 ns/div; B Time Base 50 ms/div to 50 ns/div; A and B ×10 magnifier extends max sweep to 5 ns/div
Trigger Source INT (CH1, CH2), LINE, EXT (AC, DC, DC ÷ 10)
Probes Two P6108A 100 MHz ×10 probes, BNC connector with a readout pin
Power 90 − 250 VAC, 48 − 440 Hz, 40 W max

Links

Pictures