2335: Difference between revisions
No edit summary |
No edit summary |
||
(10 intermediate revisions by 3 users not shown) | |||
Line 1: | Line 1: | ||
{{Oscilloscope Sidebar| | {{Oscilloscope Sidebar | ||
|manufacturer=Tektronix | |||
image=Tek 2335 front.jpg | | |series=2000-series scopes | ||
caption=Tektronix 2335 | | |model=2335 | ||
introduced=1982 | | |image=Tek 2335 front.jpg | ||
discontinued= | |caption=Tektronix 2335 | ||
summary=Ruggedized 100 MHz dual trace scope | | |introduced=1982 | ||
manuals= | |discontinued=1991 | ||
|designers= | |||
* [[Media:070- | |summary=Ruggedized 100 MHz dual-trace scope | ||
* [[Media:070- | |manuals= | ||
* [[Media:070-4115-00.pdf|Tektronix 2335 Operator Manual]] (PDF, OCR, bad-OCR) | |||
* [[Media:070-4116-00.pdf|Tektronix 2335 Service Manual]] | |||
* [[Media:Tektronix-2300-Series_Brochure.pdf| Tektronix 2300 Series Brochure ]] (PDF) | * [[Media:Tektronix-2300-Series_Brochure.pdf| Tektronix 2300 Series Brochure ]] (PDF) | ||
* [[Media:2300_Series_Brochure.pdf| Tektronix 2300 Series Brochure ]] (PDF, OCR) | * [[Media:2300_Series_Brochure.pdf| Tektronix 2300 Series Brochure ]] (PDF, OCR) | ||
}} | }} | ||
The '''Tektronix 2335''' is a ruggedized portable dual-channel, 100 MHz analog scope. An External trigger input on front and External Z-Axis connector at the rear round out its connectivity. | |||
The Tektronix 2335 is a ruggedized portable dual-channel, 100 MHz analog scope. An External trigger input on front and External Z-Axis connector at the rear round out its connectivity | |||
Vertical controls were by way of calibrated deflection factors on CH 1 or CH 2 inputs through AC, DC, or GND coupling. The vertical mode selections are CH 1, BOTH, CH 2, ADD, ALT, CHOP (500 kHz), TRIG VIEW, or BW LIMIT (20 MHz). Horizontal deflection is controlled by either the calibrated A or B Sweep Generators, or Alternate between the two of the A, and B Delayed Sweep. | Vertical controls were by way of calibrated deflection factors on CH 1 or CH 2 inputs through AC, DC, or GND coupling. The vertical mode selections are CH 1, BOTH, CH 2, ADD, ALT, CHOP (500 kHz), TRIG VIEW, or BW LIMIT (20 MHz). Horizontal deflection is controlled by either the calibrated A or B Sweep Generators, or Alternate between the two of the A, and B Delayed Sweep. | ||
Line 22: | Line 22: | ||
{{BeginSpecs}} | {{BeginSpecs}} | ||
{{Spec | Bandwidth | {{Spec | Bandwidth | 100 MHz (≥90 MHz at 2 mV/Div) }} | ||
{{Spec | Deflection | {{Spec | Deflection | CH1, CH2: 5 mV/Div to 5 V/Div, 1–2–5; all ±2%; Variable control can increase sensitivity to at least 2 mV/Div }} | ||
{{Spec | Input Impedance| 1 MΩ ±2% | {{Spec | Input Impedance | 1 MΩ ±2% // 20±2 pF }} | ||
{{Spec | Maximum Input | {{Spec | Maximum Input | 400 V (DC + peak AC) or 500 V (p-p ac at ≤ 1 kHz) }} | ||
{{Spec | Sweep | {{Spec | Sweep | A Time Base 0.5 s/div to 50 ns/div; B Time Base 50 ms/div to 50 ns/div; A and B ×10 magnifier extends max sweep to 5 ns/div }} | ||
{{Spec | Trigger Source| INT (CH1, | {{Spec | Trigger Source | INT (CH1, CH2), LINE, EXT (AC, DC, DC ÷ 10) }} | ||
{{Spec | Probes| Two | {{Spec | Probes | Two P6108A 100 MHz ×10 probes, BNC connector with a readout pin }} | ||
{{Spec | Power| | {{Spec | Power | 90 − 250 VAC, 48 − 440 Hz, 40 W max }} | ||
{{EndSpecs}} | {{EndSpecs}} | ||
==Links== | ==Links== | ||
* [[Media:Tekscope 1981 V13 | * [[Media:Tekscope 1981 V13 N2.pdf | TekScope Vol. 13 No. 2, June 1981]] p.10+: Three New Portable Oscilloscopes Designed for Field Service Use | ||
==Pictures== | ==Pictures== | ||
Line 43: | Line 43: | ||
</gallery> | </gallery> | ||
[[Category:2300 series scopes]] | |||
[[Category:Manual needed]] |
Revision as of 14:23, 28 January 2022
The Tektronix 2335 is a ruggedized portable dual-channel, 100 MHz analog scope. An External trigger input on front and External Z-Axis connector at the rear round out its connectivity.
Vertical controls were by way of calibrated deflection factors on CH 1 or CH 2 inputs through AC, DC, or GND coupling. The vertical mode selections are CH 1, BOTH, CH 2, ADD, ALT, CHOP (500 kHz), TRIG VIEW, or BW LIMIT (20 MHz). Horizontal deflection is controlled by either the calibrated A or B Sweep Generators, or Alternate between the two of the A, and B Delayed Sweep.
Trigger modes may be one of four modes: Single Sweep Reset, P-P Auto-TV Line, Normal, and TV Field. Trigger sources can be Internal, Line, or External, and can be controlled by amplitude level and slope type. The Internal signal source(s) is(are) from signals applied to channels 1 or 2, or based on what Vertical Mode selected.
Key Specifications
Bandwidth | 100 MHz (≥90 MHz at 2 mV/Div) |
---|---|
Deflection | CH1, CH2: 5 mV/Div to 5 V/Div, 1–2–5; all ±2%; Variable control can increase sensitivity to at least 2 mV/Div |
Input Impedance | 1 MΩ ±2% // 20±2 pF |
Maximum Input | 400 V (DC + peak AC) or 500 V (p-p ac at ≤ 1 kHz) |
Sweep | A Time Base 0.5 s/div to 50 ns/div; B Time Base 50 ms/div to 50 ns/div; A and B ×10 magnifier extends max sweep to 5 ns/div |
Trigger Source | INT (CH1, CH2), LINE, EXT (AC, DC, DC ÷ 10) |
Probes | Two P6108A 100 MHz ×10 probes, BNC connector with a readout pin |
Power | 90 − 250 VAC, 48 − 440 Hz, 40 W max |
Links
- TekScope Vol. 13 No. 2, June 1981 p.10+: Three New Portable Oscilloscopes Designed for Field Service Use