2467: Difference between revisions

From TekWiki
Jump to navigation Jump to search
(Removed redirect to 2465A)
Tag: Removed redirect
No edit summary
 
(9 intermediate revisions by 3 users not shown)
Line 10: Line 10:
|designers=Art Metz; Ken Schlotzhauer; Walt Ainsworth
|designers=Art Metz; Ken Schlotzhauer; Walt Ainsworth
|manuals=
|manuals=
* [[Media:050-2180-06.pdf|24x5A/2467 Firmware Release Notes]]
==2467==
* [[Media:070-5857-00.pdf|24x5A Options Service]] (OCR PDF, 26M)
* [[Media:070-5854-00.pdf|2467 Operators Manual 070-5854-00]]
* [[Media:070-6014-00.pdf|24x5A Operator]]
* [[Media:070-5857-00.pdf|24x5A/2467 Options Service 070-5857-00]] (OCR)
* [[Media:070-6017-00.pdf|2455A/2445A Service]] (OCR PDF, 20M)
* [[Media:070-6019-01.pdf|2465A/2467 Service Manual 070-6019-01]] (OCR)
* [[Media:070-6019-01.pdf|2465A/2467 Service]] (OCR PDF, 29M)
* [[Media:070-6291-00.pdf|Tektronix 2445/2465/2467 Buffer Test Kit 070-6291-00]]
* [[Media:070-6291-00.pdf|Tektronix 2445/2465/2467 Buffer Test Kit (PDF, needs OCR)]]
* [[Media:050-2180-06.pdf|24x5A/2467 Firmware Release Notes 050-2180-06]]
 
==2467B==
* [[Media:070-6861-01.pdf|Tek 2467B Oscilloscope and Options Operators Manual 070-6861-01]]
* [[Media:070-6861-02.pdf|Tek 2467B Oscilloscope and Options Operators Manual 070-6861-02]]
* [[Media:070-6863-00.pdf|Tektronix 2465B/2467B Service Manual 070-6863-00]]
* [[Media:070-6863-01.pdf|Tektronix 2465B/2467B Service Manual 070-6863-01]]
* [[Media:070-6864-02.pdf|Tek 24X5B 2467B Options Service Manual 070-6864-02]]
* [[Media:24xxB_Catalog_Pages.pdf|24xxB Catalog Pages]]
* [[Media:2467B option 06 to 09 upgrade.pdf|2467B - Upgrading option 06 to option 09]]
}}
}}
The '''2467''' and '''2467B''' are the same as the [[2465A]], except that the 2465A uses a conventional CRT while the 2467 and 2467B use a [[micro-channel plate CRT]] that enables bright traces at fast sweep rates, particularly with one-shot or low repetition rate signals.
The '''2467''' and '''2467B''' are the same as the [[2465A]], except that the 2465A uses a conventional CRT while the 2467 and 2467B use a [[micro-channel plate CRT]] that enables bright traces at fast sweep rates, particularly with one-shot or low repetition rate signals.<br>
The '''2567BHD''' variant is identical to the 2467B with the addition of Options 5H and 06 included.


The 2467 is from the penultimate generation of analog Tektronix scopes.
The 2467 is from the penultimate generation of analog Tektronix scopes.


The horizontal amplifier was designed by [[Art Metz]] and [[Ken Schlotzhauer]]. Art Metz also worked on the triggers. Art Metz and [[Walt Ainsworth]] designed the sweeps.
The horizontal amplifier was designed by [[Art Metz]] and [[Ken Schlotzhauer]]. Art Metz also worked on the triggers. Art Metz and [[Walt Ainsworth]] designed the sweeps.
'''Options'''
* Option 01 (DMM) added a 4½-digit, fully autoranging digital multimeter which measures DC and AC voltage and current, resistance, dBV, dBm, continuity, and temperature.
* Option 05 (TV) added TV (back-porch) clamp circuitry to the Channel 2 input and TV trigger coupling modes, allowing selection of either horizontal or vertical sync pulses to obtain horizontal-line-sync or field-sync pulse triggering.
* Option 06 (Counter/Timer/Trigger) allows precision time-interval measurement, event and frequency counting, delay-by-events triggering, and logic triggering.
* Option 09 added option 06, the CTT, plus a 17-bit [[P6407|P6407 word recognizer probe]].
* Option 10 added a [[GPIB interface]] for remote control.
* Option 11 added two [[LEMO S-series connector|probe-power connectors]] on the rear panel of the instrument.  Only shown in the 1987 catalogue.


{{BeginSpecs}}
{{BeginSpecs}}
Line 43: Line 45:
{{EndSpecs}}
{{EndSpecs}}


==See also==
==ROM Images==
* [[2465]]
* [[Media:2467_U2160_160-3302-06.zip|160-3302-06]](ZIP)
* [[2465B]]
* [[Media:2467_U2260_160-3303-06.zip|160-3303-06]](ZIP)
* [[2445 PSU Repairs|PSU Repairs]]
 
* [[Media:160-3302-09.bin|160-3302-09.bin]]
* [[Media:160-3303-09.bin|160-3303-09.bin]]
 
==Options==
* Option 01 - (DMM) added a 4½-digit, fully autoranging digital multimeter which measures DC and AC voltage and current, resistance, dBV, dBm, continuity, and temperature.
* Option 05 - (TV) added TV (back-porch) clamp circuitry to the Channel 2 input and TV trigger coupling modes, allowing selection of either horizontal or vertical sync pulses to obtain horizontal-line-sync or field-sync pulse triggering.
* Option 05H - High-definition Television (As above but supports HDTV) - 2467B only
* Option 06 - (Counter/Timer/Trigger) allows precision time-interval measurement, event and frequency counting, delay-by-events triggering, and logic triggering.
* Option 09 - Add option 06, the CTT, plus a 17-bit [[P6407|P6407 word recognizer probe]].
* Option 10 - Add a [[GPIB interface]] for remote control.
* Option 11 - Add two [[LEMO S-series connector|probe-power connectors]] on the rear panel of the instrument.  Only shown in the 1987 catalogue.
* Option 1R - Shipped with a 19" rack mount kit fitted.
* For accessories, see [[2467/Accessories]].
 
==Gerbers==
* [[Media:2467B_Flex_PCB_gerber.zip|Front panel flex PCB gerber files]]
 
==Links==
* [https://www.youtube.com/watch?v=v9KaTgChudw Tektronix 2467B "Bright Eye (tm)" Oscilloscope – 1992 Tek sales video] by vintageTek Museum @ YouTube
* [https://www.youtube.com/watch?v=NjHbfbtNhyY Tektronix 2467B Oscilloscope Restoration] by NFM @ YouTube
* See also [[2465]], [[2465B]], [[2445 PSU Repairs|PSU Repairs]]
{{Documents|Link=2467}}


==Pictures==
==Pictures==
Line 53: Line 77:
Tek 2467 rear.jpg
Tek 2467 rear.jpg
</gallery>
</gallery>
{{Parts|2467}}
{{Parts|2467B}}




[[Category:246x series scopes]]
[[Category:246x series scopes]]
[[Category:Introduced in 1986]]
[[Category:Micro-channel plate CRTs]]
[[Category:Micro-channel plate CRTs]]

Latest revision as of 11:15, 29 January 2024

Manuals – Specifications – Links – Pictures

The 2467 and 2467B are the same as the 2465A, except that the 2465A uses a conventional CRT while the 2467 and 2467B use a micro-channel plate CRT that enables bright traces at fast sweep rates, particularly with one-shot or low repetition rate signals.
The 2567BHD variant is identical to the 2467B with the addition of Options 5H and 06 included.

The 2467 is from the penultimate generation of analog Tektronix scopes.

The horizontal amplifier was designed by Art Metz and Ken Schlotzhauer. Art Metz also worked on the triggers. Art Metz and Walt Ainsworth designed the sweeps.

Key Specifications

Bandwidth 350 MHz (2467B: 400 MHz)
Sweep Rate 500 ps/div
Channels Four independent channels
Vertical 2 mV/div vertical sensitivity
Cursors Delta Volts and Delta Time Cursors
CRT Readout Scale Factors, Trigger Level, Voltage, Time, Frequency, Phase and Ratio Measurements and Mode Indicators
Trigger 500 MHz min.; Advanced Triggering with "Hands Off" Auto Level Triggering
Input Impedance 50 Ω/1 MΩ inputs with 50 Ω protection
Probes Two or four P6136 ×10 probes, 1.3 m

ROM Images

Options

  • Option 01 - (DMM) added a 4½-digit, fully autoranging digital multimeter which measures DC and AC voltage and current, resistance, dBV, dBm, continuity, and temperature.
  • Option 05 - (TV) added TV (back-porch) clamp circuitry to the Channel 2 input and TV trigger coupling modes, allowing selection of either horizontal or vertical sync pulses to obtain horizontal-line-sync or field-sync pulse triggering.
  • Option 05H - High-definition Television (As above but supports HDTV) - 2467B only
  • Option 06 - (Counter/Timer/Trigger) allows precision time-interval measurement, event and frequency counting, delay-by-events triggering, and logic triggering.
  • Option 09 - Add option 06, the CTT, plus a 17-bit P6407 word recognizer probe.
  • Option 10 - Add a GPIB interface for remote control.
  • Option 11 - Add two probe-power connectors on the rear panel of the instrument. Only shown in the 1987 catalogue.
  • Option 1R - Shipped with a 19" rack mount kit fitted.
  • For accessories, see 2467/Accessories.

Gerbers

Links

Documents Referencing 2467

Pictures


Some Parts Used in the 2467

Part Part Number(s) Class Description Used in
155-0237-00 155-0237-00 Hybrid integrated circuit vertical output amplifier 2445 2465 2466 2467
155-0238-00 155-0238-00 Hybrid integrated circuit preamplifier 11302A 2424L 2430 2430A 2432 2445 2465 2466 2467
155-0241-02 155-0241-01 155-0241-02 Monolithic integrated circuit horizontal output stage 2445 2465 2466 2467 11302A
155-0244-00 155-0244-00 Monolithic integrated circuit display sequencer 2445 2465 2466 2467
165-2235-03 165-2235-03 Hybrid integrated circuit preamplifier 2215 2252 2445 2465 2467


Some Parts Used in the 2467B

Part Part Number(s) Class Description Used in
155-0242-00 155-0242-00 155-0242-01 Hybrid integrated circuit Z-axis amplifier and autofocus 2215 2252 2440 2445 2445B 2465 2465B 2467B