Page values for "2714"

Jump to navigation Jump to search

"Specifications" values

18 rows are stored for this page
Parameter   Frequency
Value   

9 kHz to 1.8 GHz; Preamp limited to 600 MHz

Parameter   Frequency Span
Value   

1 kHz/div to 100 MHz/div in 1, 2, 5 sequence (plus 0 Hz and MAX: 180 MHz/div)

Parameter   Resolution Bandwidth
Value   

-6 dB bandwidth selections are 300 Hz, 1 kHz, 3 kHz, 10 kHz, 30 kHz, 100 kHz, 300 kHz, 1 MHz and 5 MHz

Parameter   RF Input impedance
Value   

75 Ω

Parameter   Maximum Safe Input Power
Value   

+70 dBmV (0.1 W or 2.2 V) continuous peak, ≤100 V DC blocking capacitor

Parameter   RF Attenuator
Value   

0 dB to 50 dB, 2 dB steps

Parameter   Sensitivity (at 300 Hz RBW)
Value   

-78 dBmV (-127 dBm); -90 dBmV (-139 dBm) with preamp on

Parameter   Reference Level
Value   

-70 dBm to +20 dBm; -23 dBmV to +66.9 dBmV

Parameter   Sweep Speed
Value   

2 sec/Div to 1 µs/Div in 1, 2, 5 sequence

Parameter   Triggering Modes
Value   

Free Run, Internal, External, Line, TV Line, and TV Field

Parameter   Displayed Average Noise
Value   

−66 dBm to −100 dBm

Parameter   Display Dynamic Range
Value   

80 dB

Parameter   Dynamic Range
Value   

≥100 dBm

Parameter   Internal Calibrator
Value   

100 MHz marker at +18.8 dBmV (-30 dBm)

Parameter   Included Accessories
Value   

PC Software; Power Cord; User Manual; Programmer Manual; Software Reference Manual; Front Cover; 75Ω BNC Connector, 75Ω F Connector; Choice of GPIB or RS-232 (Opt. 03 or Opt. 08)

Parameter   Weight
Value   

Standard accessories: 11.34 kg (25 lbs); Basic configuration: 10.21 kg (22.5 lbs)

Parameter   Power
Value   

90 − 132 VAC, 48 to 440 Hz; 90 – 250 VAC, 48 to 63 Hz. At 115 VAC, 60 Hz, 90 W (standard), 105 W max (with options)

Parameter   Operating Atmospherics
Value   

Temperatures: 0 °C to +50 °C; Humidity: MIL-T-28800E; Altitude: Up to 4.6 km (15,000 ft)

"Products" values

1 row is stored for this page
Manufacturer   Tektronix
Model   2714
Class   Spectrum Analyzer
Description   

1.8 GHz Spectrum Analyzer

Introduced   1993
Discontinued   2000