Line 8: Line 8:
transistor.  The Sziklai pair is non-inverting and has a voltage gain
transistor.  The Sziklai pair is non-inverting and has a voltage gain
greater than unity, which allows the overall gain of the 282 to be trimmed for exactly unity
greater than unity, which allows the overall gain of the 282 to be trimmed for exactly unity
gain.
gain. The risetime is 3ns when driven from a 25-ohm source.
 
The risetime is 3ns when driven from a 25-ohm source.


* [http://w140.com/tek_282.pdf Tektronix 282 Manual (PDF)]
* [http://w140.com/tek_282.pdf Tektronix 282 Manual (PDF)]

Revision as of 16:22, 12 December 2010

The Tektronix Type 282 is an active adapter introduced in 1966 that allows high-impedance probes to be used with instruments that have 50-ohm inputs. It is a unity-gain buffer with an input impedance of 1 megohm in parallel with 16.5 picofarads and a low output impedance. The high-impedance input stage is a dual-JFET where transistor A operates as a source-follower and transistor B operates as a current source biased with Vgs=0, maintaining a constant current through transistor A, independent of input signal voltage. After the FET input stage, the signal is fed to a Sziklai pair formed of a PNP transistor first, driving an NPN output transistor. The Sziklai pair is non-inverting and has a voltage gain greater than unity, which allows the overall gain of the 282 to be trimmed for exactly unity gain. The risetime is 3ns when driven from a 25-ohm source.