3T2: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
No edit summary
(8 intermediate revisions by 3 users not shown)
Line 1: Line 1:
{{Plugin Sidebar 2 |
{{Plugin Sidebar
title=Tektronix 3T2 |
|manufacturer=Tektronix
summary=Sampling Timebase |
|series=560-series scopes
series=[[560-series scopes]] |
|type=3T2
image=3t2 front.jpg |
|summary=Sampling Timebase
caption=Tektronix 3T2 |
|image=3t2 front.jpg
introduced=1967 |
|caption=Tektronix 3T2
discontinued=(?) |
|introduced=1967
manuals=
|discontinued=(?)
* [http://bama.edebris.com/download/tek/3t2/3t2.djvu Tektronix 3T2 Manual (DjVu)]
|manuals=
* [http://w140.com/tek_3t2.pdf Tektronix 3T2 Manual (PDF)]
* [[Media:070-0631-00.pdf|Tektronix 3T2 Manual]]<br /><small>Alternate: [http://bama.edebris.com/download/tek/3t2/3t2.djvu DjVu @ BAMA]</small>
* [[Media:Tek 3t2 fcp aug 1967.pdf|Tektronix Factory Calibration Procedure]]
* [[Media:Tek 3t2 cal outline.pdf|Tektronix 3T2 Calibration Outline]] (OCR)
* [[Media:Tek 3T2 schematics.pdf|Tektronix 3T2 Schematics]] (full-page scan)
}}
}}
The '''Tektronix 3T2''' is a [[sampling oscilloscope|sampling]] time-base plug-in
The '''Tektronix 3T2''' is a [[sampling oscilloscope|sampling]] time-base plug-in for [[560-series scopes]].  
for [[560-series scopes]].  


==Specifications==
==Specifications==
Line 20: Line 22:
The amount of jitter depends on the mode of operation.   
The amount of jitter depends on the mode of operation.   
The lowest jitter, specified to be less than 2 ps, is obtained with  
The lowest jitter, specified to be less than 2 ps, is obtained with  
an external 50 Ω trigger source of at least 150 mV, which is .   
an external 50 Ω trigger source of at least 150 mV.   
 
==Links==
* [[Media:Service Scope 46 Oct 1967.pdf | Service Scope 46, October 1967]]


==Pictures==
==Pictures==
<gallery>
<gallery>
Image:3t2 front.jpg
3t2 front.jpg
Image:3t2 left.jpg
3t2 left.jpg
Image:3t2 trigger closeup.jpg
3t2 trigger closeup.jpg
Image:3t2 trigger board.jpg
3t2 trigger board.jpg
</gallery>
</gallery>


[[Category:560 series plugins]]
[[Category:560 series plugins]]
[[Category:Sampling plugins]]
[[Category:Sampling plugins]]

Revision as of 13:15, 22 November 2022

Tektronix 3T2
Sampling Timebase
Tektronix 3T2

Compatible with 560-series scopes

Produced from 1967 to (?)

Manuals
(All manuals in PDF format unless noted otherwise)
Manuals – Specifications – Links – Pictures

The Tektronix 3T2 is a sampling time-base plug-in for 560-series scopes.

Specifications

Triggering works up to 100 MHz. The 3T2 has a random sampling mode. UHF SYNC works up to 3 GHz. The amount of jitter depends on the mode of operation. The lowest jitter, specified to be less than 2 ps, is obtained with an external 50 Ω trigger source of at least 150 mV.

Links

Pictures