The '''Tektronix Type 3T4''' is a [[sampling oscilloscope|sampling]] sweep plug-in for [[560-series scopes]] that is remotely programmable, allowing computer-controlled measurements of high-speed repetitive waveforms. It interfaces with a [[6R1A]] plug-in in a Type [[567]] scope. It was [[introduced in 1965]]. | The '''Tektronix Type 3T4''' is a [[sampling oscilloscope|sampling]] sweep plug-in for [[560-series scopes]] that is remotely programmable, allowing computer-controlled measurements of high-speed repetitive waveforms. It interfaces with a [[6R1A]] plug-in in a Type [[567]] scope. It was [[introduced in 1965]]. | ||
Line 33: | Line 33: | ||
<gallery> | <gallery> | ||
3t4_front.jpg|front view | |||
3t4_left.jpg|left view | |||
3t4_right.jpg|right view | |||
3t4_top.jpg|top view | |||
3t4_bottom.jpg|bottom view | |||
Tek 3t4 1965 cat.jpg|Description in 1965 Tek Catalog | |||
Smpte apr1965 3t4.png|In April 1965 SMPTE Journal | |||
</gallery> | </gallery> | ||
{{Parts|3T4}} | |||
[[Category:560 series plugins]] | [[Category:560 series plugins]] |
Revision as of 15:34, 10 October 2021
The Tektronix Type 3T4 is a sampling sweep plug-in for 560-series scopes that is remotely programmable, allowing computer-controlled measurements of high-speed repetitive waveforms. It interfaces with a 6R1A plug-in in a Type 567 scope. It was introduced in 1965.
Specifications
The equivalent-time sweep rate ranges from 1 ns/div to 200 μs/div. There is a 10x calibrated horizontal magnification mode that can be selected, providing 100 ps/div horizontal scale. The maximum trigger frequency is 1 GHz.
The sweep can be controlled by the staircase ramp generator in the 3T4, manually by a front-panel knob, or remotely by a control voltage sent to the 3T4.
The remotely programmable functions are
- Equivalent-time sweep rate
- Delay time
- Samples per sweep
- Normal or single-display mode
- Single-display start
See Also
Pictures
-
front view
-
left view
-
right view
-
top view
-
bottom view
-
Description in 1965 Tek Catalog
-
In April 1965 SMPTE Journal
Some Parts Used in the 3T4
Part | Part Number(s) | Class | Description | Used in |
---|---|---|---|---|
8056 | 154-0417-00 | Vacuum Tube (Triode) | low-voltage Nuvistor triode | 422 • 502 • W • 1S1 • 3A7 • 3S3 • 3T4 • 5T3 • 10A1 |